Peak deconvolution in high-field asymmetric waveform ion mobility spectrometry (FAIMS) to characterize macromolecular conformations

被引:28
作者
Robinson, Errol W. [1 ]
Sellon, Rachel E. [1 ]
Williams, Evan R. [1 ]
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
关键词
FAIMS; lysozyme; protein conformation; PEG; poly(ethylene glycol);
D O I
10.1016/j.ijms.2006.09.011
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Protonated poly(ethylene glycol), produced by electrospray ionization (ESI), with molecular weights ranging from 0.3 to 5 kDa and charge states from 1+ to 7+ were characterized using high-field asymmetric waveform ion mobility spectrometry (FAIMS). Results for all but some of the 3+ and 4+ charge states are consistent with a single gas-phase conformer or family of unresolved conformers for each of these charge states. The FAIMS compensation voltage scans resulted in peaks that could be accurately fit with a single Gaussian for each peak. The peak widths increase linearly with compensation voltage for maximum ion transmission but do not depend on m/z or molecular weight. Fitting parameters obtained from the poly(ethylene glycol) data were used to analyze conformations of oxidized and reduced lysozyme formed from different solutions. For oxidized lysozyme formed from a buffered aqueous solution, a single conformer (or group of unresolved conformers) was observed for the 7+ and 8+ charge states. Two conformers were observed for the 9+ and 10+ charge states formed from more denaturing solutions. Data for the fully reduced form indicate the existence of up to three different conformers for each charge state produced directly by ESI and a general progression from a more extended to a more folded structure with decreasing charge state. These results are consistent with those obtained previously by proton-transfer reactivity and drift tube ion mobility experiments, although more conformers were identified for the fully reduced form of lysozyme using FAIMS. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 95
页数:9
相关论文
共 45 条
[21]   Development of high-throughput liquid chromatography injected ion mobility quadrupole time-of-flight techniques for analysis of complex peptide mixtures [J].
Lee, YJ ;
Hoaglund-Hyzera, CS ;
Barnes, CAS ;
Hilderbrand, AE ;
Valentine, SJ ;
Clemmer, DE .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 782 (1-2) :343-351
[22]  
Mason E. A., 1988, TRANSPORT PROPERTIES
[23]   Nanoflow LC/ion mobility/CID/TOF for proteomics: analysis of a human urinary Proteome [J].
Moon, MH ;
Myung, S ;
Plasencia, M ;
Hilderbrand, AE ;
Clemmer, DE .
JOURNAL OF PROTEOME RESEARCH, 2003, 2 (06) :589-597
[24]   Development of high-sensitivity ion trap ion mobility spectrometry time-of-flight techniques:: A high-throughput nano-LC-IMS-TOF separation of peptides arising from a Drosophila protein extract [J].
Myung, S ;
Lee, YJ ;
Moon, MH ;
Taraszka, J ;
Sowell, R ;
Koeniger, S ;
Hilderbrand, AE ;
Valentine, SJ ;
Cherbas, L ;
Cherbas, P ;
Kaufmann, TC ;
Miller, DF ;
Mechref, Y ;
Novotny, MV ;
Ewing, MA ;
Sporleder, CR ;
Clemmer, DE .
ANALYTICAL CHEMISTRY, 2003, 75 (19) :5137-5145
[25]   Investigation of bovine ubiquitin conformers separated by high-field asymmetric waveform ion mobility spectrometry: Cross section measurements using energy-loss experiments with a triple quadrupole mass spectrometer [J].
Purves, RW ;
Barnett, DA ;
Ells, B ;
Guevremont, R .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (08) :738-745
[26]   Electrospray ionization high-field asymmetric waveform ion mobility spectrometry-mass spectrometry [J].
Purves, RW ;
Guevremont, R .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2346-2357
[27]   Separation of protein conformers using electrospray-high field asymmetric waveform ion mobility spectrometry-mass spectrometry [J].
Purves, RW ;
Barnett, DA ;
Guevremont, R .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 197 :163-177
[28]   Mass spectrometric characterization of a high-field asymmetric waveform ion mobility spectrometer [J].
Purves, RW ;
Guevremont, R ;
Day, S ;
Pipich, CW ;
Matyjaszczyk, MS .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (12) :4094-4105
[29]   Enhanced mixture analysis of poly(ethylene glycol) using high-field asymmetric waveform ion mobility spectrometry combined with Fourier transform ion cyclotron resonance mass spectrometry [J].
Robinson, EW ;
Garcia, DE ;
Leib, RD ;
Williams, ER .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2190-2198
[30]   Multidimensional separations of ubiquitin conformers in the gas phase: Relating ion cross sections to H/D exchange measurements [J].
Robinson, EW ;
Williams, ER .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (09) :1427-1437