Reducing susceptibility artifacts in fMRI using volume-selective z-shim compensation

被引:59
作者
Du, Yiping P.
Dalwani, Manish
Wylie, Korey
Claus, Eric
Tregellas, Jason R.
机构
[1] Univ Colorado Denver & Hlth Sci Ctr, Brain Imaging Ctr, Dept Psychiat, Aurora, CO 80010 USA
[2] Univ Colorado, Dept Psychol, Boulder, CO 80309 USA
关键词
fMRI; echo-planar imaging; susceptibility artifact; z-shim compensation; orbitofrontal cortex;
D O I
10.1002/mrm.21150
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Susceptibility-induced magnetic field gradients (SFGs) can result in severe signal loss in the orbitofrontal cortex (OFC) in gradient-echo-based functional MRI (fMRI) studies. Although conventional z-shim techniques can effectively recover the MRI signal in this region, the substantial penalty in imaging time hampers their use in routine fMRI studies. A modified z-shim technique with high imaging efficiency is presented in this study. In this technique, z-shim compensations are applied only to a selective volume where the susceptibility artifact is severe. The results of an fMRI study (N = 6) demonstrate the feasibility of detecting the OFC activation with z-shim in whole-brain fMRI studies at a temporal resolution of 2 s.
引用
收藏
页码:396 / 404
页数:9
相关论文
共 37 条
[1]  
Brett M AJ, 2002, NEUROIMAGE, V16, P372
[2]   Numerical calculations of the static magnetic field in three-dimensional multi-tissue models of the human head [J].
Collins, CM ;
Yang, B ;
Yang, QX ;
Smith, MB .
MAGNETIC RESONANCE IMAGING, 2002, 20 (05) :413-424
[3]  
Constable RT, 1999, MAGNET RESON MED, V42, P110, DOI 10.1002/(SICI)1522-2594(199907)42:1<110::AID-MRM15>3.0.CO
[4]  
2-3
[5]   Investigation of the human hippocampal formation using a randomized event-related paradigm and Z-shimmed functional MRI [J].
Constable, RT ;
Carpentier, A ;
Pugh, K ;
Westerveld, M ;
Oszunar, Y ;
Spencer, DD .
NEUROIMAGE, 2000, 12 (01) :55-62
[6]   Repetition time in echo planar functional MRI [J].
Constable, RT ;
Spencer, DD .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :748-755
[7]  
CONSTABLE RT, 1995, J MAGN RESON IMAGING, V5, P756
[8]   Compensation of susceptibility-induced signal loss in echo-planar imaging for functional applications [J].
Cordes, D ;
Turski, PA ;
Sorenson, JA .
MAGNETIC RESONANCE IMAGING, 2000, 18 (09) :1055-1068
[9]   An evaluation of the use of passive shimming to improve frontal sensitivity in fMRI [J].
Cusack, R ;
Russell, B ;
Cox, SML ;
De Panfilis, C ;
Schwarzbauer, C ;
Ansorge, R .
NEUROIMAGE, 2005, 24 (01) :82-91
[10]   Optimized EPI for fMRI studies of the orbitofrontal cortex [J].
Deichmann, R ;
Gottfried, JA ;
Hutton, C ;
Turner, R .
NEUROIMAGE, 2003, 19 (02) :430-441