Reducing susceptibility artifacts in fMRI using volume-selective z-shim compensation

被引:59
作者
Du, Yiping P.
Dalwani, Manish
Wylie, Korey
Claus, Eric
Tregellas, Jason R.
机构
[1] Univ Colorado Denver & Hlth Sci Ctr, Brain Imaging Ctr, Dept Psychiat, Aurora, CO 80010 USA
[2] Univ Colorado, Dept Psychol, Boulder, CO 80309 USA
关键词
fMRI; echo-planar imaging; susceptibility artifact; z-shim compensation; orbitofrontal cortex;
D O I
10.1002/mrm.21150
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Susceptibility-induced magnetic field gradients (SFGs) can result in severe signal loss in the orbitofrontal cortex (OFC) in gradient-echo-based functional MRI (fMRI) studies. Although conventional z-shim techniques can effectively recover the MRI signal in this region, the substantial penalty in imaging time hampers their use in routine fMRI studies. A modified z-shim technique with high imaging efficiency is presented in this study. In this technique, z-shim compensations are applied only to a selective volume where the susceptibility artifact is severe. The results of an fMRI study (N = 6) demonstrate the feasibility of detecting the OFC activation with z-shim in whole-brain fMRI studies at a temporal resolution of 2 s.
引用
收藏
页码:396 / 404
页数:9
相关论文
共 37 条
[11]  
DU YP, 2001, P 9 ANN M ISMRM GLAS
[12]   DIRECT FLASH MR IMAGING OF MAGNETIC-FIELD INHOMOGENEITIES BY GRADIENT COMPENSATION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (04) :474-480
[13]   BRAIN OR VEIN-OXYGENATION OR FLOW - ON SIGNAL PHYSIOLOGY IN FUNCTIONAL MRI OF HUMAN BRAIN ACTIVATION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W ;
KLEINSCHMIDT, A ;
BOECKER, H .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :45-53
[14]  
Glover GH, 1999, MAGNET RESON MED, V42, P290, DOI 10.1002/(SICI)1522-2594(199908)42:2<290::AID-MRM11>3.0.CO
[15]  
2-N
[16]   Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts [J].
Glover, GH ;
Law, CS .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :515-522
[17]   Improved combination of spiral-in/out images for BOLD fMRI [J].
Glover, GH ;
Thomason, ME .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) :863-868
[18]  
Heberlein K., 2001, P 9 ANN M ISMRM GLAS
[19]   Simultaneous acquisition of gradient-echo and asymmetric spin-echo for single-shot z-shim: Z-SAGA [J].
Heberlein, KA ;
Hu, XP .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :212-216
[20]   Mitigation of susceptibility-induced signal loss in neuroimaging using localized shim coils [J].
Hsu, JJ ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) :243-248