A method to check the accuracy of dose computation using quality index: Application to scatter contribution in high energy photon beams

被引:5
作者
Caneva, S [1 ]
Rosenwald, JC [1 ]
Zefkili, S [1 ]
机构
[1] Inst Curie, Serv Phys Med, F-75005 Paris, France
关键词
accuracy-quantitative evaluation-treatment planning systems;
D O I
10.1118/1.598967
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computerized dose calculation verification is a relevant component of radiotherapy treatment planning quality assurance. The usual procedure is to compare measurements to computations for several standard situations. As cases become more complex, special test phantoms and beam arrangements must be used, and an experimental procedure must be carefully established. In this paper we follow a new methodology to prepare a set of reference data that may be used to verify the accuracy of dose calculations involving changes in the scatter component of photon beams. The advantage of this methodology is that local measurements are not required. A quantitative evaluation of dose modifications was performed by means of correction factors (CF). For this purpose, three geometrical configurations were designed (asymmetric, symmetric, and reference) where the primary component was kept constant and the scatter component was varied by changing the height (h) of lateral columns. Measurements were performed in polystyrene phantoms for seven photon beam energies. CF were derived as the ratio of the absolute dose measured at the point of interest to the absolute dose for the reference configuration, for the asymmetric and symmetric configurations, respectively. They were expressed as a function of beam quality (QI). We have verified that, for all configurations studied, CF decrease with QI. For h = 15 cm, CF remain practically constant, whatever machine technology is used [the mean values of CF for the asymmetric and symmetric cases are CFa = 1.028 (0.2% 1 s.d.) and CFs = 1.058 (0.4% 1 s.d.)]. We have developed a test protocol and we have chosen those configurations corresponding to h = 15 cm because they both present greater values of the CF and lower standard deviations. The direct application of the method is straightforward. The user can reproduce on his local TPS the three experimental configurations described in the test protocol, and then compute CF which can be compared to our reference data set for any beam quality. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00105-X].
引用
收藏
页码:1018 / 1024
页数:7
相关论文
共 20 条
[1]  
*AAPM, 1995, 55 AAPM
[2]  
[Anonymous], 1978, 29 ICRU
[3]  
CANEVA S, 1999, RADIOTHER ONCOL, V51
[4]   DEPTH-DOSE UNDER NARROW SHIELDING BLOCKS - A COMPARISON OF MEASURED AND CALCULATED DOSE [J].
DAVIS, JB ;
REINER, B .
RADIOTHERAPY AND ONCOLOGY, 1995, 34 (03) :219-227
[5]   American Association of Physicists in Medicine radiation therapy committee task group 53: Quality assurance for clinical radiotherapy treatment planning [J].
Fraass, B ;
Doppke, K ;
Hunt, M ;
Kutcher, G ;
Starkschall, G ;
Stern, R ;
Van Dyke, J .
MEDICAL PHYSICS, 1998, 25 (10) :1773-1829
[6]   DOSE BUILDUP FOR OBLIQUELY INCIDENT PHOTON BEAMS [J].
GERBI, BJ ;
MEIGOONI, AS ;
KHAN, FM .
MEDICAL PHYSICS, 1987, 14 (03) :393-399
[7]  
*ICRU, 1987, 42 ICRU
[8]   QUALITY-CONTROL OF INHOMOGENEITY CORRECTION ALGORITHMS USED IN TREATMENT PLANNING SYSTEMS [J].
KAPPAS, C ;
ROSENWALD, JC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (03) :847-858
[9]   COMPREHENSIVE QA FOR RADIATION ONCOLOGY - REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK-GROUP-40 [J].
KUTCHER, GJ ;
COIA, L ;
GILLIN, M ;
HANSON, WF ;
LEIBEL, S ;
MORTON, RJ ;
PALTA, JR ;
PURDY, JA ;
REINSTEIN, LE ;
SVENSSON, GK ;
WELLER, M ;
WINGFIELD, L .
MEDICAL PHYSICS, 1994, 21 (04) :581-618
[10]   INTERINSTITUTIONAL EXPERIENCE IN VERIFICATION OF EXTERNAL PHOTON DOSE CALCULATIONS [J].
MASTERSON, ME ;
BAREST, G ;
CHUI, CS ;
DOPPKE, KP ;
EPPERSON, RD ;
HARMS, WB ;
KRIPPNER, KE ;
MOHAN, R ;
SLESSINGER, ED ;
SONTAG, MR ;
URIE, MM ;
WALLACE, RE ;
WONG, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :37-58