Nanosensor and Breath Analyzer for Ammonia Detection in Exhaled Human Breath

被引:129
作者
Gouma, Perena [1 ]
Kalyanasundaram, Krithika [2 ]
Yun, Xiao [3 ]
Stanacevic, Milutin [3 ]
Wang, Lisheng [4 ]
机构
[1] SUNY Stony Brook, Dept Mat Sci & Engn, Stony Brook, NY 11794 USA
[2] Sensitron, Deer Pk, NY 11729 USA
[3] SUNY Stony Brook, Dept Elect & Comp Engn, Stony Brook, NY 11794 USA
[4] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V6T 1Z4, Canada
关键词
Ammonia detection; breath analyzer; chemical sensing; metal oxide-based sensors; nanosensors; BIOMARKERS; MOO3; OXYGEN;
D O I
10.1109/JSEN.2009.2036050
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
The detection and monitoring of gases in exhaled human breath up to date has been limited by the lack of appropriate materials and technologies which could rapidly and selectively identify the presence and monitor the concentration of trace levels of specific analytes-biomarkers. We present a metal oxide-based nanosensor that is highly specific to ammonia gas in breath-simulating environments at low part-per-billion concentrations. The design of a handheld breath analyzer for gas detection in exhaled human breath is described. Semiconducting ceramics are presented as suitable sensor materials for easy and affordable noninvasive diagnostics.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 15 条
[1]
ARTERBERY VE, 1994, FREE RADICAL BIO MED, V17, P569
[2]
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure [J].
Davies, S ;
Spanel, P ;
Smith, D .
KIDNEY INTERNATIONAL, 1997, 52 (01) :223-228
[3]
Kalyanasundaram K. (Iyer), 2007, THESIS SUNY STONY BR
[4]
Human breath isoprene and its relation to blood cholesterol levels: new measurements and modeling [J].
Karl, T ;
Prazeller, P ;
Mayr, D ;
Jordan, A ;
Rieder, J ;
Fall, R ;
Lindinger, W .
JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (02) :762-770
[5]
Exhaled markers of pulmonary disease [J].
Kharitonov, SA ;
Barnes, PJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (07) :1693-1722
[6]
Biomarkers of some pulmonary diseases in exhaled breath [J].
Kharitonov, SA ;
Barnes, PJ .
BIOMARKERS, 2002, 7 (01) :1-32
[7]
Phillips M., 2002, Disease markers in exhaled breath - Detection of volatile organic compounds in breath, P219
[8]
Prasad A.K., 2005, Study of gas specificity in molybdenum trioxide/tungsten oxide thin film sensors and their arrays
[9]
Reactively sputtered MoO3 films for ammonia sensing [J].
Prasad, AK ;
Gouma, PI ;
Kubinski, DJ ;
Visser, JH ;
Soltis, RE ;
Schmitz, PJ .
THIN SOLID FILMS, 2003, 436 (01) :46-51
[10]
Comparison of sol-gel and ion beam deposited MoO3 thin film gas sensors for selective ammonia detection [J].
Prasad, AK ;
Kubinski, DJ ;
Gouma, PI .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 93 (1-3) :25-30