All-polyethylene and metal-backed tibias have similar outcomes at 10 years - A randomized level II evidence study

被引:51
作者
Gioe, Terence J. [1 ]
Stroemer, Erik S. [1 ]
Santos, Edward R. G. [1 ]
机构
[1] Univ Minnesota, Sch Med, Dept Orthopaed Surg, Dept Vet Affairs Med Ctr, Minneapolis, MN 55417 USA
关键词
D O I
10.1097/01.blo.0000238863.69486.97
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The advantages of a monoblock design and lower cost have generated renewed interest in all-polyethylene tibial components for total knee arthroplasty (TKA). We hypothesized an all-polyethylene design would function equivalently to a metal-backed modular design at lower cost and at long-term followup. We report the 8- to 12-year followup of our earlier reported prospective randomized comparison of a modern congruent all-polyethylene tibial component with a modular metal-backed tibial component of the same design. The mean age of the patients was 69 years and 92% were diagnosed with osteoarthritis. Of 290 patients (316 total knee arthroplasties) enrolled, 120 patients died, 22 had revision surgery, and one was lost to followup. We followed the remaining 147 patients (167 TKAs: 97 all-polyethylene/70 metal-backed) clinically and radiographically. There were no differences in knee function (Knee Society clinical score, range of motion, stability) or radiographic parameters between the groups. Of the 22 revisions, only three were performed for tibial aseptic loosening (three metal-backed). Ten-year survivorship of the all-polyethylene tibial component was 91.6% with revision for any reason and 100% for aseptic loosening. The metal-backed tibial component survivorship was 88.9% with revision for any reason and 94.3% for aseptic loosening. The contemporary all-polyethylene tibial component functioned equivalently to its monoblock counterpart and was less costly. Level of Evidence: Level 11, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:212 / 218
页数:7
相关论文
共 38 条
[1]
Low-conforming all-polyethylene tibial component not inferior to metal-backed component in cemented total knee arthroplasty -: Prospective, randomized radiostereometric analysis study of the AGC total knee prosthesis [J].
Adalberth, G ;
Nilsson, KG ;
Byström, S ;
Kolstad, K ;
Milbrink, J .
JOURNAL OF ARTHROPLASTY, 2000, 15 (06) :783-792
[2]
All-polyethylene versus metal-backed and stemmed tibial components in cemented total knee arthroplasty -: A prospective, randomised RSA study [J].
Adalberth, G ;
Nilsson, KG ;
Byström, S ;
Kolstad, K ;
Milbrink, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :825-831
[3]
APEL DM, 1991, CLIN ORTHOP RELAT R, V273, P243
[4]
The effectiveness of isolated tibial insert exchange in revision total knee arthroplasty [J].
Babis, GC ;
Trousdale, RT ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01) :64-68
[5]
PERFORMANCE OF THE TIBIAL COMPONENT IN TOTAL KNEE REPLACEMENT - CONVENTIONAL AND REVISION DESIGNS [J].
BARTEL, DL ;
BURSTEIN, AH ;
SANTAVICCA, EA ;
INSALL, JN .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (07) :1026-1033
[6]
THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[7]
Backside wear of modular ultra-high molecular weight polyethylene tibial inserts [J].
Conditt, MA ;
Ismaily, SK ;
Alexander, JW ;
Noble, PC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05) :1031-1037
[8]
Backside wear of polyethylene tibial inserts: Mechanism and magnitude of material loss [J].
Conditt, MA ;
Thompson, MT ;
Usrey, MM ;
Ismaily, SK ;
Noble, PC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (02) :326-331
[9]
DENNIS DA, 1992, CLIN ORTHOP RELAT R, V281, P168
[10]
DUFFY GP, 1998, CLIN ORTHOP RELAT R, V356, P66