Effect of Diameter and Length on Stress Distribution of the Alveolar Crest around Immediate Loading Implants

被引:88
作者
Ding, Xi [1 ]
Liao, Sheng-Hui [2 ]
Zhu, Xing-Hao [1 ]
Zhang, Xiu-Hua [1 ]
Zhang, Lin [1 ]
机构
[1] Affiliated Hosp 1, Wenzhou Med Coll, Dept Stomatol, Wenzhou 325000, Zhejiang, Peoples R China
[2] Zhejiang Univ, State Key Lab CAD&CG, Hangzhou 310003, Zhejiang, Peoples R China
关键词
automatic mesh generator; biomechanics; complete range mandible; dental implant; diameter; finite element analyses; immediate loading; length; stress; FINITE-ELEMENT-ANALYSIS; FIXED PARTIAL PROSTHESES; DENTAL IMPLANTS; ORAL IMPLANTS; BONE; DESIGN;
D O I
10.1111/j.1708-8208.2008.00124.x
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Background: Many clinical observations have shown that immediate loading is indicated when the stabilization of the bone/implant is optimal and when the estimated loads are not excessively high. Nonetheless, more experimental studies are needed to consider the immediate loading protocol as a safe procedure. Mechanical analysis using the finite element (FE) method analysis has been employed by many authors to understand the biomechanical behavior around dental implants. Purpose: This study was to evaluate the effect of the diameter and length on the stress and strain distribution of the crestal bone around implants under immediate loading. Materials and Methods: By an ad hoc automatic mesh generator, high-quality FE models of complete range mandible was constructed from computer tomography, with three Straumann (Straumann Institute, Waldenburg, Switzerland) implants of various sizes embedded in the anterior zone. The implant diameter ranged from 3.3 to 4.8 mm, and length ranged from 6 to 14 mm, resulting in seven designs. The implant-bone interface was simulated by nonlinear frictional contact algorithm. For each design, vertical and oblique loadings of 150 N were applied, respectively, to each implant, and stresses and strains in the surrounding cortical bone were evaluated. Results: The biomechanics analysis provided results that the oblique loading would induce significantly higher interfacial stresses and strains than the vertical loading, while the intergroup stress difference significant levels was evaluated using t-tests method and the level of significance (.05) that was accepted for significance. Under both loadings, the maximal values were recorded in the 3.3 (diameter) x 10 (length) mm implant configuration, whose mean and peak values were both higher than that of others with significant statistical differences. The second maximal one is 4.1 x 6 mm configuration, and the minimal stresses were recorded in 4.8 x 10 mm configuration, whose strains were also near to lowest. Conclusions: Increasing the diameter and length of the implant decreased the stress and strain on the alveolar crest, and the stress and strain values notably increased under buccolingual loading as compared with vertical loading, but diameter had a more significant effect than length to relieve the crestal stress and strain concentration.
引用
收藏
页码:279 / 287
页数:9
相关论文
共 36 条
[1]
Akca K, 2001, Implant Dent, V10, P238
[2]
Akça K, 2001, INT J ORAL MAX IMPL, V16, P722
[3]
Implant prosthodontic management of partially edentulous patients missing posterior teeth: The Toronto experience [J].
Attard, NJ ;
Zarb, GA .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (04) :352-359
[4]
Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog [J].
Barbier, L ;
Vander Sloten, J ;
Krzesinski, G ;
Schepers, E ;
Van Der Perre, G .
JOURNAL OF ORAL REHABILITATION, 1998, 25 (11) :847-858
[5]
Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis [J].
Bozkaya, D ;
Muftu, S ;
Muftu, A .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (06) :523-530
[6]
Brunski J B, 1988, J Dent Educ, V52, P775
[7]
Brunski J B, 1999, Adv Dent Res, V13, P99
[8]
Callan D P, 1998, Implant Dent, V7, P258, DOI 10.1097/00008505-199807040-00003
[9]
Evaluation of design parameters of osseointegrated dental implants using finite element analysis [J].
Chun, HJ ;
Cheong, SY ;
Han, JH ;
Heo, SJ ;
Chung, JP ;
Rhyu, IC ;
Choi, YC ;
Baik, HK ;
Ku, Y ;
Kim, MH .
JOURNAL OF ORAL REHABILITATION, 2002, 29 (06) :565-574
[10]
Çiftçi Y, 2000, INT J ORAL MAX IMPL, V15, P571