Immunosensor with a controlled orientation of antibodies by using NeutrAvidin-protein A complex at immunoaffinity layer

被引:54
作者
Chung, J. W.
Park, J. M.
Bernhardt, R.
Pyun, J. C.
机构
[1] KIST Europe fGmbH, D-66123 Saarbrucken, Germany
[2] Univ Saarland, D-66041 Saarbrucken, Germany
关键词
orientation; NeutrAvidin-protein A complex; CEA; SPR biosensor;
D O I
10.1016/j.jbiotec.2006.05.010
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The orientation of antibody was controlled by using NeutrAvidin-protein A complex on the gold surface of SPR biosensor. The surface density of receptor antibody (anti-hIgG) was compared by treatment of receptor antibody to the layer of avidin, NeutrAvidin, protein A, NeutrAvidin-protein A complex and bare gold surface of SPR biosensor. The ligand antibody (hIgG) was injected to each IA layer and the binding ratio of ligand antibody per unit receptor was estimated as a parameter of orientation control. The NeutrAvidin-protein A complex on gold surface of SPR biosensor showed the highest surface density of receptor antibody as well as the binding ratio of ligand antibody per receptor antibody. The NeutrAvidin-protein A complex was also prepared on biotin-labelled SAM, and the binding ratio of ligand per receptor was found to be significantly improved in comparison to the IA layer prepared by chemical coupling of receptor antibody to the SAM layer. The NeutrAvidin-protein A complex which showed the highest efficiency for the binding of ligand antibodies, was applied for the detection of a cancer marker called CEA. By using NeutrAvidin-protein A complex and sandwich assay for signal amplification, sensitivity was improved to be 1.5-fold higher than bare gold surface and the detection of CEA with the detection limit of 30 ng/ml was achieved. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:325 / 333
页数:9
相关论文
共 28 条
[1]   A COMPARATIVE-STUDY OF PROTEIN IMMOBILIZATION TECHNIQUES FOR OPTICAL IMMUNOSENSORS [J].
AHLUWALIA, A ;
DEROSSI, D ;
RISTORI, C ;
SCHIRONE, A ;
SERRA, G .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (03) :207-214
[2]   Effectiveness of protein A for antibody immobilization for a fiber optic biosensor [J].
Anderson, GP ;
Jacoby, MA ;
Ligler, FS ;
King, KD .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (04) :329-336
[3]   Study on orientation of immunogrlobulin G on protein G layer [J].
Bae, YM ;
Oh, BK ;
Lee, W ;
Lee, WH ;
Choi, JW .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :103-110
[4]   Direct oriented immobilization of F(ab′) antibody fragments on gold [J].
Brogan, KL ;
Wolfe, KN ;
Jones, PA ;
Schoenfisch, MH .
ANALYTICA CHIMICA ACTA, 2003, 496 (1-2) :73-80
[5]   Performance of the Spreeta 2000 integrated surface plasmon resonance affinity sensor [J].
Chinowsky, TM ;
Quinn, JG ;
Bartholomew, DU ;
Kaiser, R ;
Elkind, JL .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3) :266-274
[6]   Application of SPR biosensor for medical diagnostics of human hepatitis B virus (hHBV) [J].
Chung, JW ;
Kim, SD ;
Bernhardt, R ;
Pyun, JC .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 :416-422
[7]   Biosensors in clinical chemistry [J].
D'Orazio, P .
CLINICA CHIMICA ACTA, 2003, 334 (1-2) :41-69
[8]   Structured thin films as functional components within biosensors [J].
Davis, F ;
Higson, SPJ .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :1-20
[9]   Self-assembled monolayers: a versatile tool for the formulation of bio-surfaces [J].
Ferretti, S ;
Paynter, S ;
Russell, DA ;
Sapsford, KE ;
Richardson, DJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (09) :530-540
[10]   USE OF STAPHYLOCOCCAL PROTEIN-A AS AN IMMUNOLOGICAL REAGENT [J].
GODING, JW .
JOURNAL OF IMMUNOLOGICAL METHODS, 1978, 20 (APR) :241-253