Evaluation of computer-based area and volume measurement from coronal computed tomography scans in isolated blowout fractures of the orbital floor

被引:121
作者
Ploder, O
Klug, C
Voracek, M
Burggasser, G
Czerny, C
机构
[1] Univ Vienna, Sch Med, Clin Cranio & Maxillofacial Surg, Vienna, Austria
[2] Univ Vienna, Sch Med, Dept Psychoanal & Psychotherapy, Stat & Documentat Branch, Vienna, Austria
[3] Univ Vienna, Sch Med, Dept Ophthalmol, Vienna, Austria
[4] Univ Vienna, Sch Med, Dept Radiol Osteol, Vienna, Austria
关键词
D O I
10.1053/joms.2002.35722
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: In this retrospective study, we evaluated isolated blowout fractures of the orbital floor by region-of-interest measurements from coronal computed tomography (CT) scans and their relationship to ophthalmologic findings. Patients and Methods: Fracture area and volume of displaced tissue of blowout fractures in 38 patients were measured from coronal CT scans. Measurement was performed by identifying distances (for area calculation) of the fracture and identifying areas (for volume calculation) of the displaced tissue in each CT slice. The calculated data were then compared with the amount of enophthalmos, presence of diplopia, and limitation of ocular motility. Results: Orbital floor area (mean+/-SD) was 5.72+/-1.07 cm(2); fracture area, 2.63+/-1.20 cm(2); and the volume of displaced tissue, 1.15+/-0.91 mL. The average proportion of the fracture within the orbital floor was 45.3+/-17.6%. Fracture area and volume of displaced tissue were significantly positively correlated with enophthalmos and diplopia and not correlated with the limitation of ocular motility. For enophthalmos of 2 turn or greater, mean fracture area (mean+/-SD) was 4.08+/-1.09 cm(2) and volume of displaced tissue was 1.89+/-1.19 mL; for less than 2-mm enophthalmos, 1.98+/-0.83 cm(2) and 0.83+/-0.58 mL, respectively. Enophthalmos of 2 nun can be expected with 3.38 cm(2) of fracture area and 1.62 mL of displaced tissue. Conclusions: Region-of-interest measurement from coronal CT scan has an application in the assessment of patients with pure blowout fractures of the orbital floor and adds useful information in posttraumatic evaluation of orbital fractures. (C) 2002 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:1267 / 1272
页数:6
相关论文
共 19 条
[1]   Diplopia after surgical repair of orbital floor fractures [J].
Biesman, BS ;
Hornblass, A ;
Lisman, R ;
Kazlas, M .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 12 (01) :9-16
[2]   Pure orbital blowout fracture: New concepts and importance of medial orbital blowout fracture [J].
Burm, JS ;
Chung, CH ;
Oh, SJ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 103 (07) :1839-1849
[3]   ORBITAL VOLUME MEASUREMENT IN THE MANAGEMENT OF PURE BLOWOUT FRACTURES OF THE ORBITAL FLOOR [J].
CHARTERIS, DG ;
CHAN, CH ;
WHITEHOUSE, RW ;
NOBLE, JL .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (02) :100-102
[4]  
CHRISTIANSEN EL, 1986, ACTA ODONTOL SCAND, V44, P221, DOI 10.3109/00016358608997724
[5]   Measurement of orbital volume by a 3-dimensional software program:: An experimental study [J].
Deveci, M ;
Öztürk, S ;
Sengezer, M ;
Pabuscu, Y .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 58 (06) :645-648
[6]   VOLUME MEASUREMENTS OF NORMAL ORBITAL STRUCTURES BY COMPUTED TOMOGRAPHIC ANALYSIS [J].
FORBES, G ;
GEHRING, DG ;
GORMAN, CA ;
BRENNAN, MD ;
JACKSON, IT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (01) :149-154
[7]  
GILBARD SM, 1985, OPHTHALMOLOGY, V92, P1523
[8]  
Harris G J, 1998, Trans Am Ophthalmol Soc, V96, P329
[9]   DIPLOPIA, ENOPHTHALMOS, AND MOTILITY DISORDERS IN PURE BLOW-OUT FRACTURES [J].
HARTMANN, N ;
HAASE, W .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1987, 191 (02) :116-119
[10]  
Jin HR, 2000, J ORAL MAXIL SURG, V58, P617