Dual Energy Versus Single Energy MDCT: Measurement of Radiation Dose Using Adult Abdominal Imaging Protocols

被引:95
作者
Ho, Lisa M. [1 ]
Yoshizumi, Terry T. [1 ]
Hurwitz, Lynne M. [1 ]
Nelson, Rendon C. [1 ]
Marin, Daniele [1 ]
Toncheva, Greta [1 ]
Schindera, Sebastian T. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
Dual Energy CT; Virtual Non-contrast image reconstruction; liver CT; renal CT; aortic CT; EFFECT TRANSISTOR TECHNOLOGY; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; STONES; LIVER; DIFFERENTIATION;
D O I
10.1016/j.acra.2009.05.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Rationale and Objectives. The aim of this study was to measure the radiation dose of dual-energy and single-energy multi-detector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. Materials and Methods. Dual-energy CT (DECT) imaging was performed on a conventional 64-detector CT scanner using a software upgrade (Volume Dual Energy) at tube voltages of 140 and 80 kVp (with tube currents of 385 and 675 mA, respectively), with a 0.8-second gantry revolution time in axial mode. Parameters for single-energy CT (SECT) imaging were a tube voltage of 140 kVp, a tube current of 385 mA, a 0.5-second gantry revolution time, helical mode, and pitch of 1.375:1. The volume CT dose index (CTDIvol) value displayed on the console for each scan was recorded. Organ doses were measured using metal oxide semiconductor field-effect transistor technology. Effective dose was calculated as the sum of 20 organ doses multiplied by a weighting factor found in International Commission on Radiological Protection Publication 60. Radiation dose saving with virtual noncontrast imaging reconstruction was also determined. Results. The CTDIvol values were 49.4 mGy for DECT imaging and 16.2 mGy for SECT imaging. Effective dose ranged from 22.5 to 36.4 mSv for DECT imaging and from 9.4 to 13.8 mSv for SECT imaging. Virtual noncontrast imaging reconstruction reduced the total effective dose of multiphase DECT imaging by 19% to 28%. Conclusion. Using the current Volume Dual Energy software, radiation doses with DECT imaging were higher than those with SECT imaging. Substantial radiation dose savings are possible with DECT imaging if virtual noncontrast imaging reconstruction replaces precontrast imaging.
引用
收藏
页码:1400 / 1407
页数:8
相关论文
共 17 条
[1]
INCREASED TISSUE DIFFERENTIATION USING COLOR DISPLAY OF MULTIPLE-ENERGY CT SCANS [J].
AKUTAGAWA, WM ;
HUTH, GC ;
LEVIS, RE ;
DRIANIS, GC ;
DAVIS, RL .
RADIOLOGY, 1980, 134 (03) :739-756
[2]
Calcified vascular plaque specimens: Assessment with cardiac dual-energy multidetector CT in anthropomorphically moving heart phantom [J].
Boll, Daniel T. ;
Merkle, Elmar M. ;
Paulson, Erik K. ;
Mirza, Rizvan A. ;
Fleiter, Thorsten R. .
RADIOLOGY, 2008, 249 (01) :119-126
[3]
Coronary stent patency: Dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom [J].
Boll, Daniel T. ;
Merkle, Elmar M. ;
Paulson, Erik K. ;
Fleiter, Thorsten R. .
RADIOLOGY, 2008, 247 (03) :687-695
[4]
Dual energy CT characterization of urinary calculi: Initial in vitro and clinical experience [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Bader, Markus ;
Staehler, Michael ;
Haseke, Nicolas ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Stief, Christian G. ;
Becker, Christoph R. .
INVESTIGATIVE RADIOLOGY, 2008, 43 (02) :112-119
[5]
Characterization of human renal stones with MDCT: Advantage of dual energy and limitations due to respiratory motion [J].
Grosjean, Romain ;
Sauer, Benoit ;
Guerra, Rui Matias ;
Daudon, Michel ;
Blum, Alain ;
Felblinger, Jacques ;
Hubert, Jacques .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (03) :720-728
[6]
Pediatric cardiac-gated CT angiography: Assessment of radiation dose [J].
Hollingsworth, Caroline L. ;
Yoshizumi, Terry T. ;
Frush, Donald P. ;
Chan, Frandics P. ;
Toncheva, Greta ;
Nguyen, Giao ;
Lowry, Carolyn R. ;
Hurwitz, Lynne M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (01) :12-18
[7]
Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols [J].
Hurwitz, Lynne M. ;
Yoshizumi, Terry T. ;
Goodman, Philip C. ;
Frush, Donald P. ;
Nguyen, Giao ;
Toncheva, Greta ;
Lowry, Carolyn .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (04) :544-549
[8]
International Commission on Radiological Protection, 1991, ICRP PUBL
[9]
Radiation doses from small-bowel follow-through and abdominopelvic MDCT in Crohn's disease [J].
Jaffe, Tracy A. ;
Gaca, Ana Maria ;
Delaney, Susan ;
Yoshizumi, Terry T. ;
Toncheva, Greta ;
Nguyen, Giao ;
Frush, Donald P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (05) :1015-1022
[10]
*PHANT LAB, 2009, CATPH 500 600 MAN