The dissected aorta .1. Early anatomic changes in an in vitro model

被引:61
作者
Williams, DM [1 ]
LePage, MA [1 ]
Lee, DY [1 ]
机构
[1] YONSEI UNIV, COLL MED, DEPT DIAGNOST RADIOL, SEOUL 120749, SOUTH KOREA
关键词
aorta; dissection; flow dynamics; US;
D O I
10.1148/radiology.203.1.9122399
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To define early anatomic changes in the aorta in an in vitro hydrosta MATERIALS AND METHODS: Aortic dissections were created in explanted aortas. A small portion of the dissection flap was resected to allow free communication between the true and false lumina. The aortas were suspended in a saline bath and distended by means of a saline fluid column. By using intravascular ultrasonography, the are lengths of the outer walls of the true and false lumina and of the dissection flap were measured at increasing hydrostatic pressures and at increasing fractions of dissected wall circumference. RESULTS: The dissected aorta immediately became ectatic. At a given fraction of wall circumference involved in dissection, total aortic cross-sectional area increased with increased hydrostatic pressure. At a given hydrostatic pressure, this area increased with increased fraction of wall circumference dissected. Most of the increase was due to dilatation of the false lumen. There were minimal changes in true-lumen size. Dissection flap length, after initial contraction at the time of dissection, changed minimally with increasing pressure. CONCLUSION: Anatomic changes in the dissected aorta depend on hydrostatic pressure and on the percentage of aortic wall involved in the dissection.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 19 条
[1]  
Armstrong W F, 1996, J Am Soc Echocardiogr, V9, P646
[2]   VASCULAR COMPLICATIONS ASSOCIATED WITH SPONTANEOUS AORTIC DISSECTION [J].
CAMBRIA, RP ;
BREWSTER, DC ;
GERTLER, J ;
MONCURE, AC ;
GUSBERG, R ;
TILSON, MD ;
DARLING, RC ;
HAMMOND, G ;
MEGERMAN, J ;
ABBOTT, WM .
JOURNAL OF VASCULAR SURGERY, 1988, 7 (02) :199-209
[3]   DETERMINING SURGICAL INDICATIONS FOR ACUTE TYPE-B DISSECTION BASED ON ENLARGEMENT OF AORTIC DIAMETER DURING THE CHRONIC PHASE [J].
KATO, M ;
BAI, HZ ;
SATO, K ;
KAWAMOTO, S ;
KANEKO, M ;
UEDA, T ;
KISHI, D ;
OHNISHI, K .
CIRCULATION, 1995, 92 (09) :107-112
[4]   EXPERIMENTAL ASSESSMENT OF NEWLY DEVISED TRANSCATHETER STENT-GRAFT FOR AORTIC DISSECTION [J].
KATO, M ;
MATSUDA, T ;
KANEKO, M ;
UEDA, T ;
KURATANI, T ;
YOSHIOKA, Y ;
OHNISHI, K .
ANNALS OF THORACIC SURGERY, 1995, 59 (04) :908-915
[5]  
KATO N, 1994, JVIR, P805
[6]   USE OF A BALLOON-EXPANDABLE INTRAVASCULAR GRAFT IN THE MANAGEMENT OF TYPE-B AORTIC DISSECTION IN AN ANIMAL-MODEL [J].
MARTYANE, CH ;
SERRECOUSINE, O ;
LABORDE, JC ;
COSTES, V ;
MARY, H ;
SENAC, JP .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 6 (01) :97-103
[7]   INTRAVASCULAR STENTING OF ACUTE EXPERIMENTAL TYPE-B DISSECTIONS [J].
MOON, MR ;
DAKE, MD ;
PELC, LR ;
LIDDELL, R ;
CASTRO, LJ ;
MITCHELL, RS ;
MILLER, DC .
JOURNAL OF SURGICAL RESEARCH, 1993, 54 (04) :381-388
[8]   AORTIC DISSECTION WITH THE ENTRANCE TEAR IN THE DESCENDING THORACIC AORTA - ANALYSIS OF 40 NECROPSY PATIENTS [J].
ROBERTS, CS ;
ROBERTS, WC .
ANNALS OF SURGERY, 1991, 213 (04) :356-368
[9]  
SARRIS GE, 1992, LONG TERM RESULTS VA, P111
[10]   Aortic dissection: Percutaneous management of ischemic complications with endovascular stents and balloon fenestration [J].
Slonim, SM ;
Nyman, U ;
Semba, CP ;
Miller, DC ;
Mitchell, RS ;
Dake, MD .
JOURNAL OF VASCULAR SURGERY, 1996, 23 (02) :241-251