Robust fluoroscopic respiratory gating for lung cancer radiotherapy without implanted fiducial markers

被引:39
作者
Cui, Ying [1 ]
Dy, Jennifer G.
Sharp, Greg C.
Alexander, Brian
Jiang, Steve B.
机构
[1] Northeastern Univ, Dept Elect & Comp Engn, Boston, MA 02115 USA
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Boston, MA USA
关键词
D O I
10.1088/0031-9155/52/3/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
For gated lung cancer radiotherapy, it is difficult to generate accurate gating signals due to the large uncertainties when using external surrogates and the risk of pneumothorax when using implanted fiducial markers. We have previously investigated and demonstrated the feasibility of generating gating signals using the correlation scores between the reference template image and the fluoroscopic images acquired during the treatment. In this paper, we present an in- depth study, aiming at the improvement of robustness of the algorithm and its validation using multiple sets of patient data. Three different template generating and matching methods have been developed and evaluated: ( 1) single template method, ( 2) multiple template method, and ( 3) template clustering method. Using the fluoroscopic data acquired during patient setup before each fraction of treatment, reference templates are built that represent the tumour position and shape in the gating window, which is assumed to be at the end- of- exhale phase. For the single template method, all the setup images within the gating window are averaged to generate a composite template. For the multiple template method, each setup image in the gating window is considered as a reference template and used to generate an ensemble of correlation scores. All the scores are then combined to generate the gating signal. For the template clustering method, clustering ( grouping of similar objects together) is performed to reduce the large number of reference templates into a few representative ones. Each of these methods has been evaluated against the reference gating signal as manually determined by a radiation oncologist. Five patient datasets were used for evaluation. In each case, gated treatments were simulated at both 35% and 50% duty cycles. False positive, negative and total error rates were computed. Experiments show that the single template method is sensitive to noise; the multiple template and clustering methods are more robust to noise due to the smoothing effect of aggregation of correlation scores; and the clustering method results in the best performance in terms of computational efficiency and accuracy.
引用
收藏
页码:741 / 755
页数:15
相关论文
共 18 条
[1]
ARSLAN S, 2002, MED SCI MONITOR, V8, P493
[2]
Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers [J].
Berbeco, RI ;
Mostafavi, H ;
Sharp, GC ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19) :4481-4490
[3]
Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors [J].
Berbeco, RI ;
Jiang, SB ;
Sharp, GC ;
Chen, GTY ;
Mostafavi, H ;
Shirato, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02) :243-255
[4]
Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patients [J].
Chen, QS ;
Weinhous, MS ;
Deibel, FC ;
Ciezki, JP ;
Macklis, RM .
MEDICAL PHYSICS, 2001, 28 (09) :1850-1856
[5]
MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38
[6]
CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate [J].
Geraghty, PR ;
Kee, ST ;
McFarlane, G ;
Razavi, MK ;
Sze, DY ;
Dake, MD .
RADIOLOGY, 2003, 229 (02) :475-481
[7]
The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating [J].
Gierga, DP ;
Brewer, J ;
Sharp, GC ;
Betke, M ;
Willett, CG ;
Chen, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05) :1551-1558
[8]
Real-time tumor-tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy [J].
Harada, T ;
Shirato, H ;
Ogura, S ;
Oizumi, S ;
Yamazaki, K ;
Shimizu, S ;
Onimaru, R ;
Miyasaka, K ;
Nishimura, M ;
Dosaka-Akita, H .
CANCER, 2002, 95 (08) :1720-1727
[9]
Jain R., 1995, Machine Vision
[10]
Radiotherapy of mobile tumors [J].
Jiang, Steve B. .
SEMINARS IN RADIATION ONCOLOGY, 2006, 16 (04) :239-248