Laser light delivery systems for medical applications

被引:61
作者
Verdaasdonk, RM
vanSwol, CFP
机构
[1] Medical Laser Center, Dept. Biomed. Eng. and Clin. Phys., University Hospital Utrecht, 3508 GA Utrecht
关键词
XECL-EXCIMER-LASER; MODIFIED FIBER TIPS; CYLINDRICAL OPTICAL-FIBER; FLOW BYPASS-SURGERY; HOLLOW WAVE-GUIDES; TUNABLE DYE-LASER; YAG LASER; TISSUE ABLATION; PROSTATECTOMY DEVICES; ERB-YAG;
D O I
10.1088/0031-9155/42/5/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For medical applications, the choice of a delivery system will be governed by the characteristics of the laser system on the one hand and the tissue application on the other. The most important parts are the beam guide and the target optics. Most lasers have wavelengths in the visible and near-infrared and can be transported by silica fibres. For the mid- and far-IR other fibre materials or hollow waveguides are used. At the end of the waveguide or fibre, an optically active component is present to direct the beam and to control the power density on the target tissue. The laser beam can be delivered either by focusing handpieces and scanning devices to treat superficial areas or through microscopes, endoscopes and flexible fibres to treat areas almost anywhere inside the human body. The characteristics of the delivery systems can be determined looking at beam properties, transmission and thermal properties. The delivery of continuous wave or pulsed laser energy, contact or non-contact, will determine the contribution of optical, thermal and mechanical effects to the tissue. The practical use of laser delivery systems is illustrated by various clinical applications.
引用
收藏
页码:869 / 894
页数:26
相关论文
共 83 条
[31]  
HARRINGTON JA, 1992, P SOC PHOTO-OPT INS, V1649, P14, DOI 10.1117/12.60218
[32]  
HARRINGTON JA, 1990, SPIE MILESTONE SERIE
[33]  
HELFER D, 1994, APPL PHYS B-LASERS O, V58, P309
[34]   USE OF THE HOLMIUM - YAG LASER IN UROLOGY [J].
JOHNSON, DE ;
CROMEENS, DM ;
PRICE, RE .
LASERS IN SURGERY AND MEDICINE, 1992, 12 (04) :353-363
[35]   SOFT-TISSUE STUDIES WITH 805 NM DIODE-LASER RADIATION - THERMAL EFFECTS WITH CONTACT TIPS AND COMPARISON WITH EFFECTS OF 1064 NM ND-YAG LASER-RADIATION [J].
JUDY, MM ;
MATTHEWS, JL ;
ARONOFF, BL ;
HULTS, DF .
LASERS IN SURGERY AND MEDICINE, 1993, 13 (05) :528-536
[36]  
Katzir A., 1993, Lasers and Optical Fibers in Medicine
[37]   3-DIMENSIONAL CHARACTERIZATION OF THE LIGHT-DISTRIBUTION FROM DIFFUSING CYLINDRICAL OPTICAL-FIBER TIPS [J].
KOZODOY, RL ;
LUNDAHL, SL ;
BELL, D ;
HARRINGTON, JA .
APPLIED OPTICS, 1994, 33 (28) :6674-6682
[38]  
Lanzafame R J, 1990, J Laparoendosc Surg, V1, P33, DOI 10.1089/lps.1990.1.33
[39]  
MAGERA JJ, 1992, P SOC PHOTO-OPT INS, V1649, P2, DOI 10.1117/12.60217
[40]  