Enantioselective determination of oxprenolol in human plasma using dialysis coupled on-line to reversed-phase chiral liquid chromatography

被引:19
作者
Ceccato, A [1 ]
Toussaint, B [1 ]
Chiap, P [1 ]
Hubert, P [1 ]
Crommen, J [1 ]
机构
[1] UNIV LIEGE,INST PHARM,LAB DRUG ANAL,B-4000 LIEGE,BELGIUM
关键词
chiral analysis; oxprenolol; cellulose-based chiral stationary phase; dialysis; sample preparation; plasma;
D O I
10.1016/S0731-7085(96)01965-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully automated method for the determination of the enantiomers of oxprenolol in human plasma was developed, involving dialysis through a cellulose acetate membrane, clean-up and enrichment of the dialysate on a short precolumn and subsequent chiral liquid chromatographic (LC) analysis. All sample handling operations were executed automatically by a sample processor equipped with a robotic arm (ASTED system). The trace enrichment column (TEC) was packed with octadecylsilica. After conditioning of the TEC with the LC mobile phase and pH 3.0 acetate buffer, the sample was dialysed in the static-pulsed mode. The donor and acceptor solutions were made of pH 3.0 acetate buffer. After the enrichment step, the analyte was transferred by the LC mobile phase to the analytical column by means of a switching valve. The influence of different parameters of the dialysis process on the recovery of oxprenolol was first investigated using achiral LC conditions. The volume as well as the aspirating and dispensing flow rates of the acceptor solution were the main parameters studied. Oxprenolol was separated on a C18 stationary phase used for the enantioseparation of oxprenolol was a Chiralcel OD-R column which contained cellulose tris (3,5-dimethylphenylcarbamate) coated on silica as chiral selector. The corresponding mobile phase consisted of a mixture of pH 6.0 phosphate buffer containing NaClO4 at 0.45 M concentration and acetonitrile (70:30 v/v). UV detection was performed at 273 nm. The method developed was validated. Recoveries for each enantiomer of oxprenolol were about 80%. The method was found to be linear in the 50-2500 ng ml(-1) concentration range (r(2) = 0.999 for both enantiomers) and good results with respect to intra- and inter-day reproducibility as well as accuracy were obtained. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:1365 / 1374
页数:10
相关论文
共 36 条
[11]   DETERMINATION OF OXPRENOLOL IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, IN COMPARISON WITH GAS-CHROMATOGRAPHY AND GAS CHROMATOGRAPHY-MASS SPECTROMETRY [J].
GODBILLON, J ;
DUVAL, M ;
GOSSET, G .
JOURNAL OF CHROMATOGRAPHY, 1985, 345 (02) :365-371
[12]   INCREASED ELECTROCHEMICAL DETECTOR SENSITIVITY BY ELECTRODE SURFACE MODIFICATION [J].
GREGG, MR .
CHROMATOGRAPHIA, 1985, 20 (02) :129-133
[13]   DETERMINATION OF THE TOTAL CONCENTRATION OF HIGHLY PROTEIN-BOUND DRUGS IN PLASMA BY ONLINE DIALYSIS AND COLUMN LIQUID-CHROMATOGRAPHY - APPLICATION TO NONSTEROIDAL ANTIINFLAMMATORY DRUGS [J].
HERRAEZHERNANDEZ, R ;
VANDEMERBEL, NC ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 666 (01) :127-137
[14]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF THE ENANTIOMERS OF CARNITINE AND ACETYLCARNITINE ON A CHIRAL STATIONARY-PHASE [J].
HIROTA, T ;
MINATO, K ;
ISHII, K ;
NISHIMURA, N ;
SATO, T .
JOURNAL OF CHROMATOGRAPHY A, 1994, 673 (01) :37-43
[15]   KNOWLEDGE-BASED SYSTEM FOR THE AUTOMATED SOLID-PHASE EXTRACTION OF BASIC DRUGS FROM PLASMA COUPLED WITH THEIR LIQUID-CHROMATOGRAPHIC DETERMINATION - APPLICATION TO THE BIODETERMINATION OF BETA-RECEPTOR BLOCKING-AGENTS [J].
HUBERT, P ;
CHIAP, P ;
MOORS, M ;
BOURGUIGNON, B ;
MASSART, DL ;
CROMMEN, J .
JOURNAL OF CHROMATOGRAPHY A, 1994, 665 (01) :87-99
[16]   HPLC DETERMINATION OF VERAPAMIL AND NORVERAPAMIL IN PLASMA USING AUTOMATED SOLID-PHASE EXTRACTION FOR SAMPLE PREPARATION AND FLUOROMETRIC DETECTION [J].
HUBERT, P ;
CROMMEN, J .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (10) :2147-2170
[17]   DIRECT SEPARATION OF ENANTIOMERS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CELLULOSE TRIS(3,5-DIMETHYLPHENYLCARBAMATE) [J].
IKEDA, K ;
HAMASAKI, T ;
KOHNO, H ;
OGAWA, T ;
MATSUMOTO, T ;
SAKAI, JI .
CHEMISTRY LETTERS, 1989, (06) :1089-1090
[18]   CELLULOSIC CHIRAL STATIONARY PHASE UNDER REVERSED-PHASE CONDITION [J].
ISHIKAWA, A ;
SHIBATA, T .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (04) :859-878
[19]   DETERMINATION OF LOW-LEVELS OF OXPRENOLOL IN BLOOD OR PLASMA BY GAS-LIQUID-CHROMATOGRAPHY [J].
JACK, DB ;
RIESS, W .
JOURNAL OF CHROMATOGRAPHY, 1974, 88 (01) :173-176
[20]   AUTOMATED-ANALYSIS OF FREE AND TOTAL CONCENTRATIONS OF 3 ANTIEPILEPTIC DRUGS IN PLASMA WITH ONLINE DIALYSIS AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
JOHANSEN, K ;
KROGH, M ;
ANDRESEN, AT ;
CHRISTOPHERSEN, AS ;
LEHNE, G ;
RASMUSSEN, KE .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 669 (02) :281-288