Effect of chlorine content in feeding wastes of incineration on the emission of polychlorinated dibenzo-p-dioxins/dibenzofurans

被引:125
作者
Wang, LC
Lee, WJ
Lee, WS
Chang-Chien, GP
Tsai, PJ
机构
[1] Natl Cheng Kung Univ, Dept Environm Engn, Tainan 70101, Taiwan
[2] Cheng Shiu Inst Technol, Dept Chem Engn, Kaohsiung 833, Taiwan
[3] Natl Cheng Kung Univ, Grad Inst Environm & Occupat Hlth, Coll Med, Tainan 70428, Taiwan
关键词
PCDD/Fs; chlorine; principal component analysis; congener profiles; PAHs;
D O I
10.1016/S0048-9697(02)00306-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study attempts to clarify the effects of chlorine content in waste on the formation mechanisms of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in full scale incinerators by proposing and using the principal component analysis (PCA) to compare the congener profiles of PCDD/Fs in the. stack flue gases of 17 emission sources, including incinerators and vehicles. Four incinerators, among these 17 emission sources, were sampled and analyzed in this study, and the data for the other 13 emission sources were selected from previous studies. These 17 emission sources can be classified into four categories, including medical waste incinerators (MWIs, H1-H5), municipal solid waste incinerators (MSWIs, M1-M8), vehicle fuel combustion (unleaded gas-fueled vehicles, UGFV, diesel-fueled vehicles, DFV, n = 2) and polyvinylchloride (PVC) facility vent combustors (PVC I and PVC2, n = 2). PCA was conducted for these emission sources with the fractions of 17 2,3,7,8-congeners in the stack flue gases as variables to clarify the effect of chlorine content in feeding wastes on the emission of PCDD/Fs. From the results of PCA, we extrapolated that the threshold value of the chlorine content was at 0.8-1.1%, and the formation mechanisms of PCDD/Fs are influenced first by whether the chlorine content in the feeding waste is over or below the threshold value, then by other factors, which furnaces or APCDs represent. When the chlorine level in the waste is below the threshold value at 0.8-1.1%, the formation of PCDDs dominates, probably because the chlorine is used to chlorinate the non-substituted phenol to produce chlorophenols, which are important precursors for PCDDs. rather than chlorinate the dibenzofuran. While the chlorine level in the waste exceeds this threshold (0.8-1.1%), the rates of formation of PCDFs increase faster than those of PCDDs, probably because the chlorine content in the waste contributes to the deterioration of combustion conditions, and many products of incomplete combustion (PICs) like PAHs, will grow to a substantial level. When PCDD/Fs are formed from PAHs, the formation rates of PCDFs are higher than those of PCDDs. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:185 / 198
页数:14
相关论文
共 22 条
[1]   Fingerprints of dioxin from thermal industrial processes [J].
Buekens, A ;
Cornelis, E ;
Huang, H ;
Dewettinck, T .
CHEMOSPHERE, 2000, 40 (9-11) :1021-1024
[2]   Polychlorinated dibenzo-p-dioxins and dibenzofurans formation in incineration: Effects of fly ash and carbon source [J].
Cains, PW ;
McCausland, LJ ;
Fernandes, AR ;
Dyke, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (03) :776-785
[3]   Characterization of emissions of dioxins and furans from ethylene dichloride, vinyl chloride monomer and polyvinyl chloride facilities in the United States. Consolidated report [J].
Carroll, WF ;
Berger, TC ;
Borrelli, FE ;
Garrity, PJ ;
Jacobs, RA ;
Ledvina, J ;
Lewis, JW ;
McCreedy, RL ;
Smith, TP ;
Tuhovak, DR ;
Weston, AF .
CHEMOSPHERE, 2001, 43 (4-7) :689-700
[4]   Formation of PCDD/Fs in artificial solid waste incineration in a laboratory-scale fluidized-bed reactor: Influence of contents and forms of chlorine sources in high-temperature combustion [J].
Hatanaka, T ;
Imagawa, T ;
Takeuchi, M .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (18) :3920-3924
[5]   Comparison of 2,4,6-trichlorophenol conversion to PCDD/PCDF on a MSWI-fly ash and a model fly ash [J].
Hell, K ;
Altwicker, ER ;
Stieglitz, L ;
Addink, R .
CHEMOSPHERE, 2000, 40 (9-11) :995-1001
[6]   Formation rates of polychlorinated dibenzofurans and dibenzo-p-dioxins from polycyclic aromatic hydrocarbons, activated carbon and phenol [J].
Iino, F ;
Imagawa, T ;
Takeuchi, M ;
Sadakata, M ;
Weber, R .
CHEMOSPHERE, 1999, 39 (15) :2749-2756
[7]  
Jambu M., 1991, EXPLORATORY MULTIVAR, P125
[8]   PAH emission from the incineration of three plastic wastes [J].
Li, CT ;
Zhuang, HK ;
Hsieh, LT ;
Lee, WJ ;
Tsao, MC .
ENVIRONMENT INTERNATIONAL, 2001, 27 (01) :61-67
[9]   MECHANISM OF FORMATION OF POLYCHLORINATED DIBENZO-P-DIOXINS AND DIBENZOFURANS IN THE CATALYZED COMBUSTION OF CARBON [J].
LUIJK, R ;
AKKERMAN, DM ;
SLOT, P ;
OLIE, K ;
KAPTEIJN, F .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (02) :312-321
[10]  
NASS LI, 1998, CONVERSION FABRICATI, V4