H-point curve isolation method for coupled liquid chromatography and UV-visible spectrophotometry

被引:25
作者
Blasco-Gómez, F [1 ]
Bosch-Reig, F [1 ]
Campíns-Falcó, P [1 ]
Molins-Legua, C [1 ]
Herráez-Hernández, R [1 ]
机构
[1] Univ Valencia, Fac Quim, Dept Quim Analit, E-46100 Valencia, Spain
关键词
D O I
10.1021/ac990649q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The H-point curve isolation method (HPCIM) for the detection of unknown interferences in chromatography is proposed. The method allows one to estimate the UV-vis spectra of interfering species in a sample as well as to test the purity of the chromatographic peaks. Besides the detection of the unknown interferences in a sample, this method allows one to calculate the concentration of an analyte in the presence of unknown compounds. To illustrate the reliability of the proposed method, samples of diuretics and amphetamines have been analyzed by normal- and reversed-phase high-performance chromatography.
引用
收藏
页码:2559 / 2565
页数:7
相关论文
共 21 条
[1]   Determination of some structural features of procyanidins and related compounds by photodiode-array detection [J].
Bartolome, B ;
Hernandez, T ;
Bengoechea, ML ;
Quesada, C ;
GomezCordoves, C ;
Estrella, I .
JOURNAL OF CHROMATOGRAPHY A, 1996, 723 (01) :19-26
[2]   Curve resolution procedure for isolating the spectra of unknown interferences from the sample spectrum in analyte determinations [J].
Blasco-Gómez, F ;
Campíns-Falcó, P ;
Bosch-Reig, F ;
Guomin, L .
ANALYST, 1998, 123 (12) :2857-2863
[3]  
BOSCHREIG F, 1996, J CHROMATOGR A, V726, P57
[4]  
Campins-Falco P., 1988, ANALYST, V113, P1011, DOI DOI 10.1039/AN9881301011
[5]   GENERALIZED H-POINT STANDARD ADDITIONS METHOD FOR ANALYTE DETERMINATIONS IN UNKNOWN SAMPLES [J].
CAMPINSFALCO, P ;
VERDUANDRES, J ;
BOSCHREIG, F ;
MOLINSLEGUA, C .
ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) :323-333
[6]   Facile analysis of ribonucleotides in D,L-alpha-difluoromethylornithine-treated mouse lymphoid cells by high-performance anion-exchange column chromatography [J].
Cho, SC .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 678 (02) :344-348
[7]   EVALUATION OF DIFFERENT TECHNIQUES FOR PEAK PURITY ASSESSMENT ON A DIODE-ARRAY DETECTOR IN LIQUID-CHROMATOGRAPHY [J].
FABRE, H ;
LEBRIS, A ;
BLANCHIN, MD .
JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) :81-88
[8]   MULTICOMPONENT PRINCIPAL COMPONENT REGRESSION AND PARTIAL LEAST-SQUARES ANALYSES OF OVERLAPPED CHROMATOGRAPHIC PEAKS [J].
FAIGLE, JF ;
POPPI, RJ ;
SCARMINIO, IS ;
BRUNS, RE .
JOURNAL OF CHROMATOGRAPHY, 1991, 539 (01) :123-132
[9]   COMPUTERIZED LIBRARY SEARCH ROUTINE FOR COMPARING ULTRAVIOLET-SPECTRA OF DRUGS SEPARATED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HILL, DW ;
KELLEY, TR ;
LANGNER, KJ .
ANALYTICAL CHEMISTRY, 1987, 59 (02) :350-353
[10]   On-line liquid chromatography electrospray ionization mass spectrometry for determination of the brevetoxin profile in natural ''red tide'' algae blooms [J].
Hua, YS ;
Lu, WZ ;
Henry, MS ;
Pierce, RH ;
Cole, RB .
JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) :115-125