Toward a glucose biosensor based on surface-enhanced Raman scattering

被引:589
作者
Shafer-Peltier, KE
Haynes, CL
Glucksberg, MR
Van Duyne, RP
机构
[1] Northwestern Univ, Dept Chem, Evanston, IL 60208 USA
[2] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
关键词
D O I
10.1021/ja028255v
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This work presents the first step toward a glucose biosensor using surface-enhanced Raman spectroscopy (SERS). Historically, glucose has been extremely difficult to detect by SERS because it has a small normal Raman cross section and adsorbs weakly or not at all to bare silver surfaces. In this paper, we report the first systematic study of the direct detection of glucose using SERS. Glucose is partitioned into an alkanethiol monolayer adsorbed on a silver film over nanosphere (AgFON) surface and thereby, it is preconcentrated within the 0-4 nm thick zone of electromagnetic field enhancement. The experiments presented herein utilize leave-one-out partial least-squares (LOO-PILS) analysis to demonstrate quantitative glucose detection both over a large (0-250 mM) and clinically relevant (0-25 mM) concentration range. The root-mean-squared error of prediction (RMSEP) of 1.8 mM (33.1 mg/dL) in the clinical study is near that desired for medical applications (11 mM, 18 mg/dL). Future studies will advance toward true in vivo, real time, minimally invasive sensing.
引用
收藏
页码:588 / 593
页数:6
相关论文
共 54 条
  • [1] [Anonymous], 2000, CHEM ANAL SERIES MON
  • [2] UV RESONANCE RAMAN-SPECTROSCOPY FOR ANALYTICAL, PHYSICAL, AND BIOPHYSICAL CHEMISTRY .2.
    ASHER, SA
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (04) : A201 - A210
  • [3] VIBRATIONAL RAMAN OPTICAL-ACTIVITY STUDY OF D-GLUCOSE
    BELL, AF
    BARRON, LD
    HECHT, L
    [J]. CARBOHYDRATE RESEARCH, 1994, 257 (01) : 11 - 24
  • [4] Multicomponent blood analysis by near-infrared Raman spectroscopy
    Berger, AJ
    Koo, TW
    Itzkan, I
    Horowitz, G
    Feld, MS
    [J]. APPLIED OPTICS, 1999, 38 (13) : 2916 - 2926
  • [5] Cameron BD, 1999, DIABETES TECHNOL THE, V1, P125
  • [6] MOLECULAR-SPECIFIC CHROMATOGRAPHIC DETECTOR USING MODIFIED SERS SUBSTRATES
    CARRON, KT
    KENNEDY, BJ
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (18) : 3353 - 3356
  • [7] Caspers PJ, 2000, J RAMAN SPECTROSC, V31, P813, DOI 10.1002/1097-4555(200008/09)31:8/9<813::AID-JRS573>3.0.CO
  • [8] 2-7
  • [9] Progress in the noninvasive, in-vivo, tissue modulated Raman spectroscopy of human blood
    Chaiken, J
    Finney, WF
    Yang, XK
    Knudson, PE
    Peterson, KP
    Peterson, CM
    Weinstock, RS
    Hagrman, D
    [J]. BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS III, 2001, 4254 : 216 - 227
  • [10] Coates JP, 2000, SPECTROSCOPY, V15, P21