Multiwalled carbon nanotubes coated fibers for solid-phase microextraction of polybrominated diphenyl ethers in water and milk samples before gas chromatography with electron-capture detection

被引:272
作者
Wang, Jun-Xia [1 ]
Jiang, Dong-Qing [1 ]
Gu, Zhi-Yuan [1 ]
Yan, Xiu-Ping [1 ]
机构
[1] Nankai Univ, Coll Chem, Key Lab Funct Polymer Mat, Minist Educ,Res Ctr Analyt Sci, Tianjin 300071, Peoples R China
基金
中国国家自然科学基金;
关键词
solid-phase microextraction; carbon nanotubes; polybrominated diphenyl ethers; gas chromatography; milk; water;
D O I
10.1016/j.chroma.2006.10.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Determination of polybrominated diphenyl ethers (PBDEs) in environmental samples has raised great concerns due to the widespread use of PBDEs and their potential risk to humans. Solid-phase microextraction (SPME) is a fast, simple, cost-effective, and green sample preparation technique and is widely used for environmental analysis, but reports on the application of SPME for determination of PBDEs are very limited, and only a few publications dealing with commercial SPME fibers are available for extraction of PBDEs. Herein, we report a novel SPME, method using multiwalled carbon nanotubes (MWCNTs) as the SPME fiber coating for gas chromatography with electron-capture detection (GC-ECD) of PBDEs in environmental samples. The MWCNTs coating gave much higher enhancement factors (616-1756) than poly (5% dibenzene-95% dimethylsiloxane) coating (139-384) and activated carbon coating (193-423). Thirty-minute extraction of 10 mL of sample solution using the MWCNTs coated fiber for GC-ECD determination yielded the limits of detection of 3.6-8.6 ng L-1 and exhibited good linearity of the calibration functions (r(2) > 0.995). The precision (RSD%, n = 4) for peak area and retention time at the 500 ng L-1 level was 6.9-8.8% and 0.6-0.9%, respectively. The developed method was successfully applied for the analysis of real samples including local river water, wastewater, and milk samples. The recovery of the PBDEs at 500 ng L-1 spiked in these samples ranged from 90 to 119%. No PBDEs were detected in the river water and skimmed milk samples, whereas in the wastewater sample, 134-215 ng L-1 of PBDEs were found. The PBDEs were detected in all whole fat milk samples, ranging from 13 to 484 ng L-1. In a semiskimmed milk sample, only BDE-47 was found at 21 ng L-1. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 39 条
  • [21] Multiwalled carbon nanotubes as solid-phase extraction adsorbent for the preconcentration of trace metal ions and their determination by inductively coupled plasma atomic emission spectrometry
    Liang, P
    Liu, Y
    Guo, L
    Zeng, J
    Lu, HB
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (11) : 1489 - 1492
  • [22] Application of multiwalled carbon nanotubes as a solid-phase extraction sorbent for chlorobenzenes
    Liu, GH
    Wang, JL
    Zhu, YF
    Zhang, XR
    [J]. ANALYTICAL LETTERS, 2004, 37 (14) : 3085 - 3104
  • [23] High extraction efficiency fiber coated with calix[4] open-chain crown ether for solid-phase microextraction of polar aromatic and aliphatic compounds
    Liu, MM
    Zeng, ZR
    Lei, Y
    Li, HB
    [J]. JOURNAL OF SEPARATION SCIENCE, 2005, 28 (17) : 2306 - 2318
  • [24] Porous layer solid phase microextraction using silica banded phases
    Liu, Y
    Shen, YF
    Lee, ML
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (02) : 190 - 195
  • [25] Dodecylsulfate-doped polypyrrole film prepared by electrochemical fiber coating technique for headspace solid-phase microextraction of polycyclic aromatic hydrocarbons
    Mohammadi, A
    Yamini, Y
    Alizadeh, N
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1063 (1-2) : 1 - 8
  • [26] In vitro estrogenicity of polybrominated flame retardants
    Nakari, T
    Pessala, P
    [J]. AQUATIC TOXICOLOGY, 2005, 74 (03) : 272 - 279
  • [27] Sample preparation: Quo Vadis?
    Pawliszyn, J
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (11) : 2543 - 2558
  • [28] Development of a solid-phase microextraction gas chromatography/tandem mass spectrometry method for polybrominated diphenyl ethers and polybrominated biphenyls in water samples
    Polo, M
    Gómez-Noya, G
    Quintana, JB
    Llompart, M
    García-Jares, C
    Cela, R
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (04) : 1054 - 1062
  • [29] Selective extraction of trace levels of polychlorinated and polybrominated contaminants by supercritical fluid-solid-phase microextraction and determination by gas chromatography/mass spectrometry. Application to aquaculture fish feed and cultured marine species
    Rodil, R
    Carro, AM
    Lorenzo, RA
    Torrijos, RC
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (07) : 2259 - 2265
  • [30] Polymer-coated synthetic fibers designed for miniaturized sample preparation process
    Saito, Y
    Nojiri, M
    Imaizumi, M
    Nakao, Y
    Morishima, Y
    Kanehara, H
    Matsuura, H
    Kotera, K
    Wada, H
    Jinno, K