Polyaniline-coated microtiter plates for use in longwave optical bioassays

被引:23
作者
Piletsky, SA
Panasyuk, TL
Piletskaya, EV
Sergeeva, TA
El'skaya, AV
Pringsheim, E
Wolfbeis, OS
机构
[1] Inst Mol Biol & Genet, UA-252143 Kiev, Ukraine
[2] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 366卷 / 08期
关键词
D O I
10.1007/s002160051575
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A technique for coating the wells of microtiter-plates with polyaniline layers and with polyaniline/enzyme layers is presented. The resulting wells are shown to be useful for assaying enzyme substrates (as exemplified for glucose via pH) and hydrogen peroxide (via the redox properties of the film). Analyte detection is based on monitoring the absorption spectra of the polyaniline, which turn purple as a result of redox processes, or green on formation of acids by enzymatic reactions. Hydrogen peroxide (a species produced by all oxidases) and glucose (which yields protons on enzymatic oxidation) have been determined in the millimolar to micromolar concentration range. High sensitivity, film stability and good reproducibility of the measurements make the system an attractive alternative to existing biosensing schemes.
引用
收藏
页码:807 / 810
页数:4
相关论文
共 12 条
[1]   Measurement of low glucose concentrations using a microelectrochemical enzyme transistor [J].
Bartlett, PN ;
Wang, JH ;
James, W .
ANALYST, 1998, 123 (02) :387-392
[2]   Characterization of a urea optical sensor based on polypyrrole [J].
de Marcos, S ;
Hortigüela, R ;
Galbán, J ;
Castillo, JR ;
Wolfbeis, OS .
MIKROCHIMICA ACTA, 1999, 130 (04) :267-272
[3]   Optical sensing of pH based on polypyrrole films [J].
deMarcos, S ;
Wolfbeis, OS .
ANALYTICA CHIMICA ACTA, 1996, 334 (1-2) :149-153
[4]   Polyaniline based optical pH sensor [J].
Grummt, UW ;
Pron, A ;
Zagorska, M ;
Lefrant, S .
ANALYTICA CHIMICA ACTA, 1997, 357 (03) :253-259
[5]   Composite films of Prussian Blue and N-substituted polypyrroles: Fabrication and application to optical determination of pH [J].
Koncki, R ;
Wolfbeis, OS .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2544-2550
[6]   Disposable integrated cuvette test for quantitative determination of vitamin C in pharmaceutical products [J].
Koncki, R ;
Lenarczuk, T ;
Glab, S .
ANALYTICA CHIMICA ACTA, 1999, 379 (1-2) :69-74
[7]   Advances in conductive polymers [J].
Kumar, D ;
Sharma, RC .
EUROPEAN POLYMER JOURNAL, 1998, 34 (08) :1053-1060
[8]   CONDUCTING POLYMER INTERACTION WITH GASEOUS SUBSTANCES .2. PANI-H2O, PANI-NH3 [J].
LUBENTSOV, BZ ;
TIMOFEEVA, ON ;
KHIDEKEL, ML .
SYNTHETIC METALS, 1991, 45 (02) :235-240
[9]   STUDIES ON THE CHEMICAL SYNTHESES AND ON THE CHARACTERISTICS OF POLYANILINE DERIVATIVES [J].
MATTOSO, LHC ;
MANOHAR, SK ;
MACDIARMID, AG ;
EPSTEIN, AJ .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1995, 33 (08) :1227-1234
[10]  
Pringsheim E, 1999, ADV MATER, V11, P865, DOI 10.1002/(SICI)1521-4095(199907)11:10<865::AID-ADMA865>3.0.CO