Evaluation of iterative reconstruction (OSEM) versus filtered back-projection for the assessment of myocardial glucose uptake and myocardial perfusion using dynamic PET

被引:19
作者
Sondergaard, Hanne M.
Madsen, Mette Marie
Boisen, Karin
Bottcher, Morten
Schmitz, Ole
Nielsen, Torsten T.
Botker, Hans Erik
Hansen, Soren B.
机构
[1] Aarhus Univ Hosp, NBG, PET Ctr, DK-8000 Aarhus C, Denmark
[2] Aarhus Univ Hosp, Dept Cardiol B, DK-8000 Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Clin Pharmacol, DK-8000 Aarhus, Denmark
[4] Aarhus Univ Hosp, Dept Endocrinol, DK-8000 Aarhus, Denmark
关键词
F-18-FDG PET; myocardial blood flow; reconstruction quantification; PET; cardiology;
D O I
10.1007/s00259-006-0198-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Iterative reconstruction methods based on ordered-subset expectation maximisation (OSEM) has replaced filtered backprojection (FBP) in many clinical settings owing to the superior image quality. Whether OSEM is as accurate as FBP in quantitative positron emission tomography ( PET) is uncertain. We compared the accuracy of OSEM and FBP for regional myocardial F-18-FDG uptake and (NH3)-N-13 perfusion measurements in cardiac PET. Methods: Ten healthy volunteers were studied. Five underwent dynamic F-18-FDG PET during hyperinsulinaemic euglycaemic clamp, and five underwent (NH3)-N-13 perfusion measurement during rest and adenosine-induced hyperaemia. Images were reconstructed using FBP and OSEM +/- an 8-mm Gaussian post-reconstruction filter. Results: Filtered and unfiltered images showed agreement between the reconstruction methods within +/- 2SD in Bland-Altman plots of K-i values. The use of a Gaussian filter resulted in a systematic underestimation of K-i in the filtered images of 11%. The mean deviation between the reconstruction methods for both unfiltered and filtered images was 1.3%. Agreement within +/- 2SD between the methods was demonstrated for perfusion rate constants up to 2.5 min(-1), corresponding to a perfusion of 3.4 ml g(-1) min(-1). The mean deviation between the two methods for unfiltered data was 2.7%, and for filtered data, 5.3%. Conclusion: The F-18-FDG uptake rate constants showed excellent agreement between the two reconstruction methods. In the perfusion range up to 3.4 ml g(-1) min(-1), agreement between (NH3)-N-13 perfusion obtained with OSEM and FBP was acceptable. The use of OSEM for measurement of perfusion values higher than 3.4 ml g(-1) min(-1) requires further evaluation.
引用
收藏
页码:320 / 329
页数:10
相关论文
共 21 条
[1]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Boellaard R, 2001, J NUCL MED, V42, p196P
[4]  
Boellaard R, 2001, J NUCL MED, V42, P808
[5]  
DEFRONZO RA, 1979, AM J PHYSIOL, V237, P214
[7]  
HOGG D, 2002, P IEEE NUCL SCI S ME, P1519
[8]   Left atrial versus left ventricular input function for quantification of the myocardial blood flow with nitrogen-13 ammonia and positron emission tomography [J].
Hove, JD ;
Iida, H ;
Kofoed, KF ;
Freiberg, J ;
Holm, S ;
Kelbaek, H .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (01) :71-76
[9]   ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609
[10]   NONINVASIVE QUANTIFICATION OF REGIONAL BLOOD-FLOW IN THE HUMAN HEART USING N-13 AMMONIA AND DYNAMIC POSITRON EMISSION TOMOGRAPHIC IMAGING [J].
HUTCHINS, GD ;
SCHWAIGER, M ;
ROSENSPIRE, KC ;
KRIVOKAPICH, J ;
SCHELBERT, H ;
KUHL, DE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (05) :1032-1042