Citrate clearance in children receiving continuous venovenous renal replacement therapy

被引:88
作者
Chadha, V
Garg, U
Warady, BA
Alon, US
机构
[1] Univ Missouri, Childrens Mercy Hosp, Sect Pediat Nephrol, Kansas City, MO 64108 USA
[2] Univ Missouri, Childrens Mercy Hosp, Dept Pathol & Lab Med, Kansas City, MO 64108 USA
关键词
continuous renal replacement therapy; bleeding; anticoagulation; citrate; clearance;
D O I
10.1007/s00467-002-0963-6
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Anticoagulation is usually indicated in patients receiving continuous renal replacement therapy (CRRT) to prevent clotting of the extra-corporeal circuit. While heparin is the most frequently used anticoagulant, regional citrate anticoagulation is becoming the preferred choice in those patients at high risk for bleeding. However, it has been widely claimed that to avoid citrate toxicity, CRRT with citrate anticoagulation should utilize diffusive clearance (e.g., continuous venovenous hemodialysis). We studied citrate clearance in five children who received citrate anticoagulation during CRRT with a COBE PRISMA machine and an M-60 (AN-69) filter. The blood flow rate ranged from 50 to 150 ml/min (2.1-8.0 ml/kg per min). Citrate was infused in the circuit circulation as an acid citrate dextrose (ACD) solution at a rate of 1.6-3.7% of the blood flow rate to maintain the circuit ionized calcium (iCa) <0.5 mmol/l. Calcium-free replacement fluid with reduced alkali (NaHCO3 20 mEq/l) was infused in pre-filter mode at a rate of 1,800-2,000 ml/h per 1.73 m(2). In a separate central line, CaCl2 (0.8%) was infused (rate 25-50% of ACD infusion) to maintain systemic iCa between 1.0 and 1.3 mmol/l. Citrate concentration was measured using an enzymatic assay. Total CRRT duration was 1,224 h. Twenty-four filters were changed due to clotting, with a mean filter life of 51 h. Mean (range) citrate levels (mmol/l) were (1) before initiating CRRT (n=2): patient baseline 0.13 (0.1-0.15), (2) during CRRT (n=7): circuit 4.54 (3.95-6.25), effluent 4.31 (3.95-5.46), and patient 0.69 (0.30-1.13). Sieving coefficients for urea and citrate were 0.88-0.97 and 0.88-1.0, respectively. Citrate clearance (31-38 ml/min per 1.73 m(2)) was similar to that of urea (31-38 ml/min per 1.73 m(2)), and when evaluated in two patients, remained unchanged after substituting half of the convective clearance [continuous venovenous hemofiltration (CVVH)] by diffusive clearance [continuous venovenous hemo-diafiltration (CVVHDF)]. The post-filter citrate load (mean+/-SD) delivered to the five patients during CRRT was 1.06+/-0.62 mmol/kg per hour. With the exception of alkalosis in one patient, no other complications were observed. Renal function recovered in all patients. We conclude that citrate anticoagulation in children is feasible, effective, and safe. Sufficient citrate clearance to prevent its toxic accumulation is achieved by convective clearance (CVVH) alone and diffusive clearance (CVVHDF) does not appear to be mandatory when utilizing citrate anticoagulation during CRRT.
引用
收藏
页码:819 / 824
页数:6
相关论文
共 35 条
  • [1] CITRATE ANTICOAGULATION DURING INVIVO SIMULATION OF SLOW HEMOFILTRATION
    AHMAD, S
    YEO, KT
    JENSEN, WM
    DELLANDICHO
    GREGORY, B
    MORITZ, JL
    KENNY, M
    [J]. BLOOD PURIFICATION, 1990, 8 (04) : 177 - 182
  • [2] A PROSPECTIVE COMPARATIVE-STUDY OF CONTINUOUS ARTERIOVENOUS HEMODIAFILTRATION AND CONTINUOUS VENOVENOUS HEMODIAFILTRATION IN CRITICALLY ILL PATIENTS
    BELLOMO, R
    PARKIN, G
    LOVE, J
    BOYCE, N
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 21 (04) : 400 - 404
  • [3] BENADOR N, 2001, PEDIAT NEPHROL C, V70
  • [4] Diffusive and convective solute clearances during continuous renal replacement therapy at various dialysate and ultrafiltration flow rates
    Brunet, S
    Leblanc, M
    Geadah, D
    Parent, D
    Courteau, S
    Cardinal, J
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 34 (03) : 486 - 492
  • [5] HEMODYNAMIC EFFECTS OF INTRAVENOUSLY ADMINISTERED SODIUM CITRATE
    BUNKER, JP
    BENDIXEN, HH
    MURPHY, AJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1962, 266 (08) : 372 - +
  • [6] Sieving coefficient inaccuracies during hemodiafiltration in patients with hyperbilirubinemia
    Chadha, V
    Garg, U
    Warady, BA
    Alon, US
    [J]. PEDIATRIC NEPHROLOGY, 2000, 15 (1-2) : 33 - 35
  • [7] Regional hemodialysis anticoagulation: Hypertonic tri-sodium citrate or anticoagulant citrate dextrose-A
    Flanigan, MJ
    Pillsbury, L
    Sadewasser, G
    Lim, VS
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1996, 27 (04) : 519 - 524
  • [8] GOLPER TA, 1988, SEMIN DIALYSIS, V1, P50
  • [9] CONTINUOUS ARTERIOVENOUS HEMOFILTRATION WITH LOW-MOLECULAR-WEIGHT HEPARIN
    HORY, B
    CACHOUX, A
    TOULEMONDE, F
    [J]. NEPHRON, 1985, 41 (01): : 125 - 125
  • [10] JEFFREY RF, 1993, ARTIF ORGANS, V17, P717