Feasibility of Functional Cardiac MR Imaging in Mice Using A Clinical 3 Tesla Whole Body Scanner

被引:25
作者
Bunck, Alexander C. [1 ]
Engelen, Markus A. [2 ]
Schnackenburg, Bernhard [3 ]
Furkert, Juliane
Bremer, Christoph
Heindel, Walter
Stypmann, Joerg [2 ]
Maintz, David
机构
[1] Univ Hosp Muenster, Inst Clin Radiol, Dept Clin Radiol, D-48149 Munster, Germany
[2] Univ Hosp Muenster, Dept Cardiol & Angiol, D-48149 Munster, Germany
[3] Philips GmbH Healthcare, Hamburg, Germany
关键词
cardiac MRI; animal imaging; heart; 3; Tesla; echocardiography; CARDIOVASCULAR MAGNETIC-RESONANCE; HEART-FAILURE; 2-DIMENSIONAL ECHOCARDIOGRAPHY; 1.5; T; MOUSE; TOMOGRAPHY; ACCURATE; DISEASE; MODELS;
D O I
10.1097/RLI.0b013e3181b2c135
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Objectives: To test the feasibility of cardiac MR imaging in mice using a clinical 3 Tesla whole body MR system for structural and functional analysis. Standard protocols for bright blood cine imaging were adapted for murine dimensions. To validate measurements of functional parameters the MR data were compared with high-resolution echocardiographic measurements. Materials and Methods: Cardiac imaging was carried out in CD I wild-type mice (n = 8). MR imaging studies were performed using a clinical 3 Tesla MR system (Achieva, Philips). All mice received 2 MR scans and I echocardiographic evaluation. For optimal MR signal detection a dedicated solenoid receive-only coil was used. Electrocardiogram signal was recorded using a dedicated small animal electrocardiogram monitoring unit. For imaging we used a retrospectively triggered TFE sequence with a repetition time of 12 ms and an echo time of 4 ms. A dedicated;oft-ware patch allowed for triggering of cardiac frequency of tip to 600 BPM. Doppler-echocardiography was performed using a VisualSonics Vevo 770 high-resolution imaging system with a 30 MHz scan-head. Axial/lateral resolution was 40 of 100 mu m and temporal resolution was 150 to 300 frames/s (B-mode) and 1000 frames/s (M-mode) depending on the setting. Results: MR imaging was successfully carried out in all mice with a sufficient temporal resolution and good signal-to-noise ratio and contrast-to-noise ratio levels allowing for identification of all relevant structures, Accordingly, there was a good scan-rescan reproducibility of MR measurements: Interassay coefficients of variance ranged from 4% for ejection fraction to 12% for endsystolic volume (ESV). Magnetic resonance imaging and echocardiography gave comparable results when using the same geometric model (Teichholz method): EDV: 60.2 +/- 6.1 mu L/59.1 +/- 12.3 mu L, ESV: 20.0 +/- 2.6 mu L/20.7 +/- 7.7 mu L, EF: 66.7% +/- 4.0%/65.2% +/- 9.9%, CO 19.5 +/- 3.6 mL/17.9 +/- 2.9 mL. Bland-Altman analysis gave acceptable limits of agreement between both methods: EDV (+28.2/-26.1), ESV (+16.3/-17.7), EF (+19/-16.1), CO (10.7/-7.5). When applying the Simpson's method MR volume estimates were significantly higher compared with echocardiography resulting in a lower estimate for the ejection fraction (60% +/- 3.9% vs. 66.7% +/- 4.0%). Conclusions: Cardiac MR imaging of mice using a clinical 3 Tesla MR system for functional analysis is feasible with sufficient spatial and temporal resolution, good repeatability and reliable results when compared with high-resolution echocardiography.
引用
收藏
页码:749 / 756
页数:8
相关论文
共 25 条
[1]
Dual in vivo magnetic resonance evaluation of magnetically labeled mouse embryonic stem cells and cardiac function at 1.5 T [J].
Arai, T ;
Kofidis, T ;
Bulte, JWM ;
de Bruin, J ;
Venook, RD ;
Berry, GJ ;
Mcconnell, MV ;
Quertermous, T ;
Robbins, RC ;
Yang, PC .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (01) :203-209
[2]
Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance - Are they interchangeable? [J].
Bellenger, NG ;
Burgess, MI ;
Ray, SG ;
Lahiri, A ;
Coats, AJS ;
Cleland, JGF ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2000, 21 (16) :1387-1396
[3]
Applying the right statistics: analyses of measurement studies [J].
Bland, JM ;
Altman, DG .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :85-93
[4]
Use of echocardiography for the phenotypic assessment of genetically altered mice [J].
Collins, KA ;
Korcarz, CE ;
Lang, RM .
PHYSIOLOGICAL GENOMICS, 2003, 13 (03) :227-239
[5]
Quantitative 3-dimensional echocardiography for accurate and rapid cardiac phenotype characterization in mice [J].
Dawson, D ;
Lygate, CA ;
Saunders, J ;
Schneider, JE ;
Ye, XJ ;
Hulbert, K ;
Noble, JA ;
Neubauer, S .
CIRCULATION, 2004, 110 (12) :1632-1637
[6]
Longitudinal follow-up of cardiac structure and functional changes in an infarct mouse model using retrospectively gated micro-computed tomography [J].
Detombe, Sarah A. ;
Ford, Nancy L. ;
Xiang, Fuli ;
Lu, Xiangru ;
Feng, Qingping ;
Drangova, Maria .
INVESTIGATIVE RADIOLOGY, 2008, 43 (07) :520-529
[7]
Cardiovascular phenotyping in mice [J].
Doevendans, PA ;
Daemen, MJ ;
de Muinck, ED ;
Smits, JF .
CARDIOVASCULAR RESEARCH, 1998, 39 (01) :34-49
[8]
MR in mouse models of cardiac disease [J].
Epstein, Frederick H. .
NMR IN BIOMEDICINE, 2007, 20 (03) :238-255
[9]
Magnetic resonance imaging and invasive evaluation of development of heart failure in transgenic mice with myocardial expression of tumor necrosis factor-α [J].
Franco, F ;
Thomas, GD ;
Giroir, B ;
Bryant, D ;
Bullock, MC ;
Chwialkowski, MC ;
Victor, RG ;
Peshock, RM .
CIRCULATION, 1999, 99 (03) :448-454
[10]
Echocardiographic assessment of left ventricular mass in neonatal and adult mice:: Accuracy of different echocardiographic methods [J].
Ghanem, Alexander ;
Roell, Willi ;
Hashemi, Toktam ;
Dewald, Oliver ;
Djoufack, P. Chryso ;
Fink, Klaus B. ;
Schrickel, Jan ;
Lewalter, Thorsten ;
Luederitz, Berndt ;
Tiemann, Klaus .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (10) :900-907