Comparison between Oxford Cobbmeter and digital Cobbmeter for measurement of Cobb angle in adolescent idiopathic scoliosis

被引:14
作者
Allam, Yasser [1 ]
El-Fiky, Tarek [1 ]
Farghally, Mahmoud Yasser [1 ]
Al-Sabagh, Sameh [1 ]
Siam, Ahmed Ezzat [1 ,2 ,3 ]
机构
[1] Univ Alexandria, Al Hadra Univ Hosp, Spine Unit, Alexandria, Egypt
[2] Schon Klin Vogtareuth, Dept Spinal Surg, 20 Krankenhausstr, D-83569 Vogtareuth, Germany
[3] Schon Klin Vogtareuth, Scoliosis Ctr, 20 Krankenhausstr, D-83569 Vogtareuth, Germany
关键词
Scoliosis; Cobb angle; Smart phone; iPhone; Cobbmeter; Tiltmeter; INTRAOBSERVER MEASUREMENT VARIABILITY; RADIOGRAPHIC-MEASUREMENT; CONGENITAL SCOLIOSIS; RELIABILITY; CHILDREN; ERROR;
D O I
10.1007/s00586-015-4162-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
The purpose of this study was to compare Cobb angle measurements performed using an Oxford Cobbmeter and digital Cobbmeter in a series of 20 adolescent idiopathic scoliosis (AIS) patients. Four observers measured major Cobb angles on 20 standing postero-anterior radiographs of AIS patients with both Oxford Cobbmeter and digital Cobbmeter (iPhone Cobbmeter Application). The measurements were repeated a week after the original measurements. The mean Cobb angle in this study was 43.6A degrees A A +/- A 23.62A degrees. The mean measurement time for an observer to measure the 20 Cobb angles was 24.9 min for the smart phone compared with 25.6 min for the Oxford Cobbmeter. The 95 % confidence interval for differences between smart phone and Oxford Cobbmeter measurements on the same radiograph was +/- 3.68A degrees. The intra-observer variability of the smart phone is equivalent to the Oxford Cobbmeter. The 95 % confidence intervals for inter-observer error were +/- 5A degrees and +/- 5.8A degrees for the smart phone and Oxford Cobbmeter, respectively. We conclude that the smart phone with integrated Tiltmeter and Cobbmeter application is an equivalent Cobb measurement tool to the Oxford Cobbmeter. The advantages of smart phone are the accuracy of determining the most inclined vertebrae and accordingly more precise Cobb angle measurement. The new smart phones with these integrated applications may be really helpful to the spine surgeons, especially in hospitals where PACS or Oxford Cobbmeter is not available.
引用
收藏
页码:444 / 449
页数:6
相关论文
共 21 条
[1]
Variability in Cobb angle measurements using reformatted computerized tomography scans [J].
Adam, CJ ;
Izatt, MT ;
Harvey, JR ;
Askin, GN .
SPINE, 2005, 30 (14) :1664-1669
[2]
VARIABILITY OF SCOLIOSIS MEASUREMENT FROM SPINAL ROENTGENOGRAMS [J].
BEEKMAN, CE ;
HALL, V .
PHYSICAL THERAPY, 1979, 59 (06) :764-765
[3]
Applying the right statistics: analyses of measurement studies [J].
Bland, JM ;
Altman, DG .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :85-93
[4]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]
MEASUREMENT OF SCOLIOSIS AND KYPHOSIS RADIOGRAPHS - INTRAOBSERVER AND INTEROBSERVER VARIATION [J].
CARMAN, DL ;
BROWNE, RH ;
BIRCH, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :328-333
[6]
The reliability of quantitative analysis on digital images of the scoliotic spine [J].
Cheung, J ;
Wever, DJ ;
Veldhuizen, AG ;
Klein, JP ;
Verdonck, B ;
Nijlunsing, R ;
Cool, JC ;
Van Horn, JR .
EUROPEAN SPINE JOURNAL, 2002, 11 (06) :535-542
[7]
Cobb J, 1948, Instr Course Lect, V5, P261
[8]
Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual [J].
Dang, NR ;
Moreau, MJ ;
Hill, DL ;
Mahood, JK ;
Raso, J .
SPINE, 2005, 30 (09) :1064-1069
[9]
DUTTON K E, 1989, Australasian Physical and Engineering Sciences in Medicine, V12, P16
[10]
Measurement accuracy in congenital scoliosis [J].
Facanha, FAM ;
Winter, RB ;
Lonstein, JE ;
Koop, S ;
Novacheck, T ;
L'Heureux, EA ;
Noren, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (01) :42-45