Reagentless amperometric carbohydrate antigen 19-9 immunosensor based on direct electrochemistry of immobilized horseradish peroxidase

被引:42
作者
Du Dan [1 ]
Xu Xiaoxing
Wang Shengfu
Zhang Aidong
机构
[1] Cent China Normal Univ, Minist Educ, Key Lab Pesticide & Chem Biol, Wuhan 430079, Peoples R China
[2] Changshu Inst Technol, Dept Chem, Changshu 215500, Peoples R China
[3] Minist Educ, Key Lab Synth & Applicat Organ Funct Mol, Wuhan 430062, Peoples R China
关键词
immunosensor; electrochemical sensors; enzyme labeled antibody; carbohydrate antigen 19-9 (CA19-9); colloidal gold nanoparticles;
D O I
10.1016/j.talanta.2006.06.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reagentless immunosensor for rapid determination of carbohydrate antigen 19-9 (CA19-9) in human serum was proposed. This strategy was based on the immobilization of antibody in colloidal gold nanoparticle modified carbon paste electrode and the direct electrochemistry of horseradish peroxidase (HRP) that was labeled to a CA 19-9 antibody. The nanoparticles were efficient for preserving the activity of immobilized biomolecules. Thus, the immobilized HRP displayed its direct electrochemistry with a rate constant of 1.02s(-1). The incubation of the immunosensor in phosphate buffer solution (PBS) including CA19-9 antigen leading to the formation of antigen-antibody complex, which made the block of electron transfer of HRP toward electrode and resulted in significant peak current decrease of HRP. Under the optimal conditions, the current decrease was proportional to CA19-9 concentrations ranging from 2 to 30U/ml with a detection limit of 1.37U/ml at a current decrease by 10%. The immunosensor showed an acceptable accuracy compared with those obtained from immunoradiometric assays, with intra-assay coefficient of 7.3 and 6.9% at CA19-9 concentrations of 5 and 15U/ml, respectively, and inter-assay coefficient of 9.6% at a CA19-9 concentration of 20U/ml. The storage stability was acceptable in a pH 7.0 PBS at 4 degrees C for 10 days. This method avoids the addition of electron transfer mediator, thus simplifies the immunoassay procedure and decreases the analytical time. It provides a new promising platform for clinical immunoassay. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1257 / 1262
页数:6
相关论文
共 34 条
[1]   Monoclonal antibody based electrochemical immunosensor for the determination of ochratoxin A in wheat [J].
Alarcon, Sergio Hugo ;
Palleschi, Giuseppe ;
Compagnone, Dario ;
Pascale, Michelangelo ;
Visconti, Angelo ;
Barna-Vetro, Ildiko .
TALANTA, 2006, 69 (04) :1031-1037
[2]   Morphology-dependent electrochemistry of cytochrome c at Au colloid-modified SnO2 electrodes [J].
Brown, KR ;
Fox, AP ;
Natan, MJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (05) :1154-1157
[3]   A gold nanoparticles/sol-gel composite architecture for encapsulation of immunoconjugate for reagentless electrochemical immunoassay [J].
Chen, J ;
Tang, JH ;
Yan, F ;
Ju, HX .
BIOMATERIALS, 2006, 27 (10) :2313-2321
[4]  
Clerico A, 2000, CLIN CHEM, V46, P1529
[5]   Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125 [J].
Dai, Z ;
Yan, F ;
Chen, J ;
Ju, HX .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5429-5434
[6]   Electrochemical immunoassay of membrane P-glycoprotein by immobilization of cells on gold nanoparticles modified on a methoxysilyl-terminated butyrylchitosan matrix [J].
Du, D ;
Ju, HX ;
Zhang, XJ ;
Chen, J ;
Cai, J ;
Chen, HY .
BIOCHEMISTRY, 2005, 44 (34) :11539-11545
[7]   Colloidal gold nanoparticle modified carbon paste interface for studies of tumor cell adhesion and viability [J].
Du, D ;
Liu, SL ;
Chen, J ;
Ju, HX ;
Lian, HZ ;
Li, JX .
BIOMATERIALS, 2005, 26 (33) :6487-6495
[8]   Immunological assay for carbohydrate antigen 19-9 using an electrochemical immunosensor and antigen immobilization in titania sol-gel matrix [J].
Du, D ;
Yan, F ;
Liu, SL ;
Ju, HX .
JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 283 (1-2) :67-75
[9]   Voltammetric determination of alkaline phosphatase and horseradish peroxidase activity using 3-indoxyl phosphate as substrate -: Application to enzyme immunoassay [J].
Fanjul-Bolado, P ;
González-García, MB ;
Costa-García, A .
TALANTA, 2004, 64 (02) :452-457
[10]   Glucose biosensor based on a reagentless graphite-epoxy screen-printable biocomposite [J].
Galan-Vidal, CA ;
Munoz, J ;
Dominguez, C ;
Alegret, S .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 45 (01) :55-62