Reagentless amperometric carbohydrate antigen 19-9 immunosensor based on direct electrochemistry of immobilized horseradish peroxidase

被引:42
作者
Du Dan [1 ]
Xu Xiaoxing
Wang Shengfu
Zhang Aidong
机构
[1] Cent China Normal Univ, Minist Educ, Key Lab Pesticide & Chem Biol, Wuhan 430079, Peoples R China
[2] Changshu Inst Technol, Dept Chem, Changshu 215500, Peoples R China
[3] Minist Educ, Key Lab Synth & Applicat Organ Funct Mol, Wuhan 430062, Peoples R China
关键词
immunosensor; electrochemical sensors; enzyme labeled antibody; carbohydrate antigen 19-9 (CA19-9); colloidal gold nanoparticles;
D O I
10.1016/j.talanta.2006.06.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reagentless immunosensor for rapid determination of carbohydrate antigen 19-9 (CA19-9) in human serum was proposed. This strategy was based on the immobilization of antibody in colloidal gold nanoparticle modified carbon paste electrode and the direct electrochemistry of horseradish peroxidase (HRP) that was labeled to a CA 19-9 antibody. The nanoparticles were efficient for preserving the activity of immobilized biomolecules. Thus, the immobilized HRP displayed its direct electrochemistry with a rate constant of 1.02s(-1). The incubation of the immunosensor in phosphate buffer solution (PBS) including CA19-9 antigen leading to the formation of antigen-antibody complex, which made the block of electron transfer of HRP toward electrode and resulted in significant peak current decrease of HRP. Under the optimal conditions, the current decrease was proportional to CA19-9 concentrations ranging from 2 to 30U/ml with a detection limit of 1.37U/ml at a current decrease by 10%. The immunosensor showed an acceptable accuracy compared with those obtained from immunoradiometric assays, with intra-assay coefficient of 7.3 and 6.9% at CA19-9 concentrations of 5 and 15U/ml, respectively, and inter-assay coefficient of 9.6% at a CA19-9 concentration of 20U/ml. The storage stability was acceptable in a pH 7.0 PBS at 4 degrees C for 10 days. This method avoids the addition of electron transfer mediator, thus simplifies the immunoassay procedure and decreases the analytical time. It provides a new promising platform for clinical immunoassay. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1257 / 1262
页数:6
相关论文
共 34 条
[31]   Direct electron transfer effect biosensors [J].
Varfolomeev, SD ;
Kurochkin, IN ;
Yaropolov, AI .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (09) :863-871
[32]   Enzyme/semiconductor nanoclusters combined systems for novel amperometric biosensors [J].
Vastarella, W ;
Nicastri, R .
TALANTA, 2005, 66 (03) :627-633
[33]   In situ assembly of colloidal particles into miniaturized biosensors [J].
Velev, OD ;
Kaler, EW .
LANGMUIR, 1999, 15 (11) :3693-3698
[34]   SPECIFIC BINDING ASSAY FOR BIOTIN BASED ON ENZYME CHANNELING WITH DIRECT ELECTRON-TRANSFER ELECTROCHEMICAL DETECTION USING HORSERADISH-PEROXIDASE [J].
WRIGHT, JD ;
RAWSON, KM ;
HO, WO ;
ATHEY, D ;
MCNEIL, CJ .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (05) :495-500