Effect of scatter radiation on image noise in cone beam CT

被引:15
作者
Endo, M [1 ]
Tsunoo, T [1 ]
Nakamori, N [1 ]
机构
[1] Natl Inst Radiol Sci, Chiba 2638555, Japan
来源
MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING | 2000年 / 3977卷
关键词
D O I
10.1117/12.384527
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cone beam CT has a capability of 3-dimensional imaging of large volumes with isotropic resolutions, and has a potentiality of 4-dimensional imaging (dynamic volume imaging) because cone beam CT acquires a large volume data with one rotation of X-ray tube-detector pair. However, one of the potential drawbacks with cone beam CT is larger amount of scattered X-rays. These X-rays may enhance the noise in reconstructed images, and thus affect low contrast detectablity. The aim of this work was to estimate scatter fractions and effects of scatter on image noise, and was to seek methods of improving image quality in cone beam CT. First we derived a relationship between the noises in reconstructed image and in X-ray intensity measurement. Then we estimated scatter to primary ratios in X-ray measurements, using a Monte Carlo simulation. From these we estimated image noise in clinical relevant conditions. The results showed that scatter radiation made a substantial contribution to the image noise. However focused collimators improved it, because they decreased scatter radiation drastically while keeping the primary radiation nearly the same level. A conventional grid also improved image noise though the improvement was less than that of focused collimators.
引用
收藏
页码:514 / 521
页数:8
相关论文
共 11 条
[1]   Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation [J].
Antonuk, LE ;
ElMohri, Y ;
Siewerdsen, JH ;
Yorkston, J ;
Huang, W ;
Scarpine, VE ;
Street, RA .
MEDICAL PHYSICS, 1997, 24 (01) :51-70
[2]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[3]  
CHSLER DA, 1977, J COMPUTER ASSISTED, V1, P64
[4]  
Endo M, 1998, Radiat Med, V16, P7
[5]  
ENDO M, IEEE T NUCL SCI, V46, P686
[6]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[7]   Image intensifier-based computed tomography volume scanner for angiography [J].
Ning, R ;
Kruger, RA .
ACADEMIC RADIOLOGY, 1996, 3 (04) :344-350
[8]  
Robb R A, 1982, IEEE Trans Med Imaging, V1, P22, DOI 10.1109/TMI.1982.4307545
[9]   IN-VIVO EVALUATION OF A NEW SYSTEM FOR 3D COMPUTERIZED ANGIOGRAPHY [J].
SAINTFELIX, D ;
TROUSSET, Y ;
PICARD, C ;
PONCHUT, C ;
ROMEAS, R ;
ROUGEE, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :583-595
[10]   FOURIER RECONSTRUCTION OF A HEAD SECTION [J].
SHEPP, LA ;
LOGAN, BF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (03) :21-43