Reliability of roentgenogram evaluation of pedicle screw position

被引:65
作者
Ferrick, MR [1 ]
Kowalski, JM [1 ]
Simmons, ED [1 ]
机构
[1] SUNY BUFFALO, DEPT ORTHOPAED SURG, BUFFALO, NY USA
关键词
pedicle screws; radiographs; spinal fixation; spine imaging;
D O I
10.1097/00007632-199706010-00016
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. This was a human cadaver study of the accuracy of biplanar roentgenography in determining pedicle screw position. Objective. To determine the independent accuracy of radiologic evaluation of screw placement and to determine if there are any particular screw malpositions that are most likely to produce a false sense of acceptable screw position. Summary of Background Data. Other investigators have reported the correlation between radiologic evaluation and anatomic dissection. However, in those studies the radiologic evaluation was not independent of the surgeons placing the screws. There has been no comment in the literature regarding particular screw malpositions that would lead the surgeon into a false sense of successful screw placement. Methods. Pedicle screws were placed in cadaver spines, and biplanar roentgenograms of the specimens were evaluated by independent observers. The results of the roentgenogram evaluation then wee compared to those of the anatomic dissection. Results. The accuracy of roentgenogram evaluation varied from 73% to 83%, depending on the experience of the surgeon grading the roentgenograms. Screws misplaced medically into the spinal canal are more likely to give the surgeon a false sense of successful screw placement. Conclusions. The surgeon must not rely solely on the roentgenograms, but instead continue to use tactile sensory skills, anatomic knowledge, and additional modalities such as electromyography monitoring.
引用
收藏
页码:1249 / 1252
页数:4
相关论文
共 12 条
[1]
STIMULUS-EVOKED EMG MONITORING DURING TRANSPEDICULAR LUMBOSACRAL SPINE INSTRUMENTATION - INITIAL CLINICAL-RESULTS [J].
CALANCIE, B ;
MADSEN, P ;
LEBWOHL, N .
SPINE, 1994, 19 (24) :2780-2786
[2]
CARL AL, 1995, N AM SPIN SOC ANN C
[3]
COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS [J].
ESSES, SI ;
SACHS, BL ;
DREYZIN, V .
SPINE, 1993, 18 (15) :2231-2239
[4]
ACCURACY OF PEDICLE SCREW PLACEMENT IN LUMBAR FUSIONS BY PLAIN RADIOGRAPHS AND COMPUTED-TOMOGRAPHY [J].
FARBER, GL ;
PLACE, HM ;
MAZUR, RA ;
JONES, DEC ;
DAMIANO, TR .
SPINE, 1995, 20 (13) :1494-1499
[5]
GLASSMAN SD, 1995, SPINE, V20, P1375, DOI 10.1097/00007632-199506000-00008
[6]
TRIGGERED ELECTROMYOGRAPHIC THRESHOLD FOR ACCURACY OF PEDICLE SCREW PLACEMENT - AN ANIMAL-MODEL AND CLINICAL CORRELATION [J].
LENKE, LG ;
PADBERG, AM ;
RUSSO, MH ;
BRIDWELL, KH ;
GELB, DE .
SPINE, 1995, 20 (14) :1585-1591
[7]
MEASUREMENT OF VERTEBRAL CORTICAL INTEGRITY DURING PEDICLE EXPLORATION FOR INTRAPEDICULAR FIXATION [J].
MYERS, BS ;
HASTY, CC ;
FLOBERG, DR ;
HOFFMAN, RD ;
LEONE, BJ ;
RICHARDSON, WJ .
SPINE, 1995, 20 (02) :144-148
[8]
INTRAOPERATIVE MONITORING FOR THORACOLUMBAR OR LUMBAR SURGERY WITH SOMATOSENSORY EVOKED-POTENTIALS AFTER DOUBLE STIMULI [J].
NISHIJIMA, Y ;
OKADA, M ;
YASUAKI, Y ;
TODA, N ;
IZUMI, T .
SPINE, 1992, 17 (11) :1304-1308
[9]
SPINAL PEDICLE FIXATION - CONFIRMATION OF AN IMAGE-BASED TECHNIQUE FOR SCREW PLACEMENT [J].
STEINMANN, JC ;
HERKOWITZ, HN ;
ELKOMMOS, H ;
WESOLOWSKI, DP .
SPINE, 1993, 18 (13) :1856-1861
[10]
THE USE OF DERMATOMAL EVOKED-RESPONSES DURING SURGICAL-PROCEDURES THAT USE INTRAPEDICULAR FIXATION OF THE LUMBOSACRAL SPINE [J].
TOLEIKIS, JR ;
CARLVIN, AO ;
SHAPIRO, DE ;
SCHAFER, MF .
SPINE, 1993, 18 (16) :2401-2407