Comparison of Two Different Minimized Extracorporeal Circulation Systems: Hematological Effects after Coronary Surgery

被引:18
作者
Haneya, Assad [1 ]
Philipp, Alois [1 ]
Diez, Claudius [1 ]
Ried, Michael [1 ]
Puehler, Thomas [1 ]
Camboni, Daniele [1 ]
Zausig, York [2 ]
Lehle, Karla [1 ]
Schmid, Christof [1 ]
机构
[1] Univ Med Ctr Regensburg, Dept Cardiothorac Surg, D-93053 Regensburg, Germany
[2] Univ Med Ctr Regensburg, Dept Anesthesiol, D-93053 Regensburg, Germany
关键词
CARDIOPULMONARY BYPASS; INFLAMMATORY RESPONSE; CENTRIFUGAL PUMP; FOLLOW-UP; BLOOD; ISOFLURANE; EXPERIENCE; TRAUMA; DAMAGE;
D O I
10.1097/MAT.0b013e3181be2f5c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiopulmonary bypass induces hemolysis and activation of inflammatory and coagulation systems as a result of a combination of mechanical trauma and biological mechanisms. The aim of our study was to evaluate the performance of two different minimized extracorporeal circulation (ECC) systems and to compare their influence on blood components. From January 2003 to December 2008, 1,218 patients underwent coronary artery bypass grafting with minimized ECC. The PRECiSe system (41%) consists of a microporous capillary membrane oxygenator (MO) and a diagonal pump (DeltaStream DP2). The MECC system (59%) is composed of a polymethylpentene MO with a plasma-tight diffusion membrane and a centrifugal pump (RotaFlow). Serial blood samples were taken preoperatively (TO), on arrival to intensive care unit (T1), 6 hours postoperatively (T2), and at discharge (T3). Demographic data, intraoperative, and technical parameters were similar in both groups. At T1 and T2, the platelet count in the PRECiSe group was significantly lower than that in the MECC group (p < 0.01). Furthermore, at T1, levels of lactate dehydrogenase were significantly higher in the PRECiSe group (p < 0.05). In addition, postoperative blood loss was significantly higher using the PRECiSe system (p < 0.05). In conclusion, cardiac surgery with the MECC system is associated with less postoperative bleeding and improved blood cell preservation. ASAIO Journal 2009; 55:592-597.
引用
收藏
页码:592 / 597
页数:6
相关论文
共 31 条
[11]  
*MAQ CARD AG, 2007, INSTR US
[12]   Centrifugal pump and heparin coating improves cardiopulmonary bypass biocompatibility [J].
Moen, O ;
Fosse, E ;
Dregelid, E ;
Brockmeier, V ;
Andersson, C ;
Hogasen, K ;
Venge, P ;
Mollnes, TE ;
Kierulf, P .
ANNALS OF THORACIC SURGERY, 1996, 62 (04) :1134-1140
[13]  
Moen Oddvar, 1994, Perfusion, V9, P109, DOI 10.1177/026765919400900205
[14]   Evaluation of platelet damage in two different centrifugal pumps based on measurements of α-granule packing proteins [J].
Mohara, J ;
Kawahito, K ;
Misawa, Y ;
Fuse, K .
ARTIFICIAL ORGANS, 1998, 22 (05) :371-374
[15]  
Mottaghy K, 1989, ASAIO Trans, V35, P640
[16]   The CentriMag: A new optimized centrifugal blood pump with levitating impeller [J].
Mueller, JP ;
Kuenzli, A ;
Reuthebuch, O ;
Dasse, K ;
Kent, S ;
Zuend, G ;
Turina, MI ;
Lachat, ML .
HEART SURGERY FORUM, 2004, 7 (05) :E477-E480
[17]   INFLUENCE OF HEMATOCRIT AND PLATELET COUNT ON IMPEDANCE AND REACTIVITY OF WHOLE-BLOOD FOR ELECTRICAL AGGREGOMETRY [J].
MULLER, MR ;
SALAT, A ;
PULAKI, S ;
STANGL, P ;
ERGUN, E ;
SCHREINER, W ;
LOSERT, U ;
WOLNER, E .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1995, 34 (01) :17-22
[18]   Small pore size microporous membrane oxygenator reduces plasma leakage during prolonged extracorporeal circulation: A case report [J].
Musch, G ;
Verweij, M ;
Bombino, M ;
Banfi, G ;
Fumagalli, R ;
Pesenti, A .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1996, 19 (03) :177-180
[19]   Less blood damage in the impeller centrifugal pump: A comparative study with the roller pump in open heart surgery [J].
Nishinaka, T ;
Nishida, H ;
Endo, M ;
Miyagishima, M ;
Ohtsuka, G ;
Koyanagi, H .
ARTIFICIAL ORGANS, 1996, 20 (06) :707-710
[20]  
OKU T, 1988, T AM SOC ART INT ORG, V34, P500