Nine-analyte detection using an array-based biosensor

被引:99
作者
Taitt, CR
Anderson, GP
Lingerfelt, BM
Feldstein, MJ
Ligler, FS
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
[2] George Mason Univ, Fairfax, VA 22030 USA
关键词
D O I
10.1021/ac0260185
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fluorescence-based multianalyte immunosensor has been developed for simultaneous analysis of multiple samples. While the standard 6 x 6 format of the array sensor has been used to analyze six samples for six different analytes, this same format has the potential to allow a single sample to be tested for 36 different agents. The method described herein demonstrates proof of principle that the number of analytes detectable using a single array can be increased simply by using complementary mixtures of capture and tracer antibodies. Mixtures were optimized to allow detection of closely related analytes without significant cross-reactivity. Following this facile modification of patterning and assay procedures, the following nine targets could be detected in a single 3 x 3 array: Staphylococcal enterotoxin B, ricin, cholera toxin, Bacillus anthracis Sterne, Bacillus globigii, Francisella tularensis LVS, Yersinia pestis F1 antigen, MS2 coliphage, and Salmonella typhimurium. This work maximizes the efficiency and utility of the described array technology, increasing only reagent usage and cost; production and fabrication costs are not affected.
引用
收藏
页码:6114 / 6120
页数:7
相关论文
共 50 条
[1]  
Anderson G. P., 2000, P 1 C POINT DET CHEM
[2]  
Anderson GP, 1999, FIELD ANAL CHEM TECH, V3, P307, DOI 10.1002/(SICI)1520-6521(1999)3:4/5<307::AID-FACT9>3.0.CO
[3]  
2-M
[4]   REMOTE FIBER-OPTIC BIOSENSORS BASED ON EVANESCENT-EXCITED FLUORO-IMMUNOASSAY - CONCEPT AND PROGRESS [J].
ANDRADE, JD ;
VANWAGENEN, RA ;
GREGONIS, DE ;
NEWBY, K ;
LIN, JN .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1985, 32 (07) :1175-1179
[5]   Protein microchips: Use for immunoassay and enzymatic reactions [J].
Arenkov, P ;
Kukhtin, A ;
Gemmell, A ;
Voloshchuk, S ;
Chupeeva, V ;
Mirzabekov, A .
ANALYTICAL BIOCHEMISTRY, 2000, 278 (02) :123-131
[6]   Immunoassay with multicomponent protein microarrays fabricated by electrospray deposition [J].
Avseenko, NV ;
Morozova, TY ;
Ataullakhanov, FI ;
Morozov, VN .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :927-933
[7]  
BAKER EE, 1947, P SOC EXP BIOL MED, V64, P139, DOI 10.3181/00379727-64-15726
[8]   Micromosaic immunoassays [J].
Bernard, A ;
Michel, B ;
Delamarche, E .
ANALYTICAL CHEMISTRY, 2001, 73 (01) :8-12
[9]   USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES [J].
BHATIA, SK ;
SHRIVERLAKE, LC ;
PRIOR, KJ ;
GEORGER, JH ;
CALVERT, JM ;
BREDEHORST, R ;
LIGLER, FS .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) :408-413
[10]   Comparison of chemical cleaning methods of glass in preparation for silanization [J].
Cras, JJ ;
Rowe-Taitt, CA ;
Nivens, DA ;
Ligler, FS .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (8-9) :683-688