Gas Chromatography/Atmospheric Pressure Chemical Ionization-Time of Flight Mass Spectrometry: Analytical Validation and Applicability to Metabolic Profiling

被引:60
作者
Carrasco-Pancorbo, Alegria [1 ]
Nevedomskaya, Ekaterina [1 ]
Arthen-Engeland, Thomas [2 ]
Zey, Thomas [2 ]
Zurek, Gabriela [2 ]
Baessmann, Carsten [2 ]
Deelder, Andre M. [1 ]
Mayboroda, Oleg A. [1 ]
机构
[1] LUMC, Biomol Mass Spectrometry Unit, Dept Parasitol, Leiden, Netherlands
[2] Bruker Daltonik GmbH, Bremen, Germany
关键词
ATMOSPHERIC-PRESSURE; AMINO-ACIDS; HUMAN SERUM; ION-SOURCE; GC-MS; URINE; GC/MS; DERIVATIZATION; LIQUID; CREATININE;
D O I
10.1021/ac9006073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gas Chromatography (GC)-Mass Spectrometry (MS) with Atmospheric Pressure (AP) interface was introduced more than 30 years ago but never became a mainstream technique, mainly because of technical difficulties and cost of instrumentation. A recently introduced multipurpose AP source created the opportunity to reconsider the importance of AP ionization for GC. Here, we present an analytical evaluation of GC/APCI-MS showing the benefits of soft atmospheric pressure chemical ionization for GC in combination with a Time of Flight (TOF) mass analyzer. During this study, the complete analytical procedure was optimized and evaluated with respect to characteristic analytical parameters, such as repeatability, reproducibility, linearity, and detection limits. Limits of detection (LOD) were found within the range from 11.8 to 72.5 nM depending on the type of compound. The intraday and interday repeatability tests demonstrate relative standard deviations (RSDs) of peak areas between 0.7%-2.1% and 3.8%-6.4% correspondingly. Finally, we applied the developed method to the analysis of human cerebrospinal fluid (CSF) samples to check the potential of this new analytical combination for metabolic profiling.
引用
收藏
页码:10071 / 10079
页数:9
相关论文
共 37 条
[1]   Extraction and GC/MS analysis of the human blood plasma metabolome [J].
A, J ;
Trygg, J ;
Gullberg, J ;
Johansson, AI ;
Jonsson, P ;
Antti, H ;
Marklund, SL ;
Moritz, T .
ANALYTICAL CHEMISTRY, 2005, 77 (24) :8086-8094
[2]   Development and Performance of a Gas Chromatography-Time-of-Flight Mass Spectrometry Analysis for Large-Scale Nontargeted Metabolomic Studies of Human Serum [J].
Begley, Paul ;
Francis-McIntyre, Sue ;
Dunn, Warwick B. ;
Broadhurst, David I. ;
Halsall, Antony ;
Tseng, Andy ;
Knowles, Joshua ;
Goodacre, Royston ;
Kell, Douglas B. .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :7038-7046
[3]   Simple Coupling of Gas Chromatography to Electrospray Ionization Mass Spectrometry [J].
Brenner, Nina ;
Haapala, Markus ;
Vuorensola, Katariina ;
Kostiainen, Risto .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :8334-8339
[4]   Intercomparison study on accurate mass measurement of small molecules in mass spectrometry [J].
Bristow, AWT ;
Webb, KS .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (10) :1086-1098
[5]   NOMENCLATURE IN EVALUATION OF ANALYTICAL METHODS INCLUDING DETECTION AND QUANTIFICATION CAPABILITIES (IUPAC RECOMMENDATIONS 1995) [J].
CURRIE, LA .
PURE AND APPLIED CHEMISTRY, 1995, 67 (10) :1699-1723
[6]   Extending the breadth of metabolite profiling by gas chromatography coupled to mass spectrometry [J].
Fiehn, Oliver .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (03) :261-269
[7]  
Fiehn Oliver, 2007, V358, P3, DOI 10.1007/978-1-59745-244-1_1
[8]  
Halket John M., 2005, Journal of Experimental Botany, V56, P219
[9]  
HORNING EC, 1977, CLIN CHEM, V23, P13
[10]   NEW PICOGRAM DETECTION SYSTEM BASED ON A MASS-SPECTROMETER WITH AN EXTERNAL IONIZATION SOURCE AT ATMOSPHERIC-PRESSURE [J].
HORNING, EC ;
HORNING, MG ;
CARROLL, DI ;
DZIDIC, I ;
STILLWELL, RN .
ANALYTICAL CHEMISTRY, 1973, 45 (06) :936-943