Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography

被引:263
作者
Germano, G
Erel, J
Lewin, H
Kavanagh, PB
Berman, DS
机构
[1] CEDARS SINAI MED CTR, DEPT MED, DIV MED PHYS, LOS ANGELES, CA 90048 USA
[2] CEDARS SINAI MED CTR, DEPT MED, DIV IMAGING & CARDIOL, LOS ANGELES, CA 90048 USA
[3] UNIV CALIF LOS ANGELES, SCH MED, DEPT RADIOL SCI, LOS ANGELES, CA 90024 USA
[4] UNIV CALIF LOS ANGELES, SCH MED, DEPT MED, LOS ANGELES, CA 90024 USA
关键词
D O I
10.1016/S0735-1097(97)00276-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. We developed an automatic quantitative algorithm for the measurement of regional myocardial wall motion and wall thickening from three-dimensional gated technetium-99m sestamibi myocardial perfusion single-photon emission computed to myographic images. Background. The algorithm measures the motion of the three-dimensional endocardial surface using a modification of the centerline method, as well as wall thickening using both geometry (gaussian fit) and partial volume (counts). Methods. The algorithm was tested using a ''variable thickness'' heart phantom, and the quantitative results were compared with visual segmental assessment of myocardial motion and thickening in 79 clinical patients with a wide range of ejection fractions (6% to 87%). Results. Phantom measurements of simulated motion and thickening were accurate regardless of the camera used (dual or triple detector), the angular span of reconstructed data (180 degrees or 360 degrees), the amount of motion (3 or 6 mm) or the amount of thickening (33%, 50% or 100%), Quantitative measurements of segmental motion and thickening in the patients were correlated with visual scares (r = 0.668, exact agreement 72.6%, kappa 0.433 and r = 0.550, exact agreement 74.7%, kappa 0.408 respectively), Significant inverse linear relations exist between the global (summed) visual motion score and the average quantitative motion, and between the global (summed) visual thickening score and the average quantitative thickening, Automatic quantitative ejection fraction measurements correlated extremely well with average quantitative motion (r = 0.929) and thickening (r = 0.959). Conclusions. Our algorithm is accurate and may be the first automatic technique for the quantitative three-dimensional assessment of regional ventricular function in cardiology. (C) 1997 by the American College of Cardiology.
引用
收藏
页码:1360 / 1367
页数:8
相关论文
共 34 条
[21]   Identification of severe and extensive coronary artery disease by automatic measurement of transient ischemic dilation of the left ventricle in dual-isotope myocardial perfusion SPECT [J].
Mazzanti, M ;
Germano, G ;
Kiat, H ;
Kavanagh, PB ;
Alexanderson, E ;
Friedman, JD ;
Hachamovitch, R ;
VanTrain, KF ;
Berman, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (07) :1612-1620
[22]   ANGULAR DISPLACEMENT OF THE PAPILLARY-MUSCLES DURING THE CARDIAC CYCLE [J].
MIRRO, MJ ;
ROGERS, EW ;
WEYMAN, AE ;
FEIGENBAUM, H .
CIRCULATION, 1979, 60 (02) :327-333
[23]  
MOUSSEAUX E, 1992, CURR OPIN RADIOL, V4, P34
[24]  
MURPHY P, 1995, DIAGNOSTIC NUCL MED, P403
[25]   RELATION OF SEGMENTAL WALL MOTION TO GLOBAL LEFT-VENTRICULAR FUNCTION IN ACUTE MYOCARDIAL-INFARCTION [J].
OHSUZU, F ;
BOUCHER, CA ;
NEWELL, JB ;
YASUDA, T ;
GOLD, HK ;
LEINBACH, RC ;
MCKUSICK, KA ;
OKADA, RD ;
ROSENTHAL, S ;
POHOST, GM ;
STRAUSS, HW .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (08) :1275-1281
[26]   QUANTIFICATION OF REGIONAL MYOCARDIAL-FUNCTION BY RAPID CINE MR IMAGING [J].
PFLUGFELDER, PW ;
SECHTEM, UP ;
WHITE, RD ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (03) :523-529
[27]   REGIONAL LEFT-VENTRICULAR WALL THICKENING BY MAGNETIC-RESONANCE-IMAGING - EVALUATION IN NORMAL PERSONS AND PATIENTS WITH GLOBAL AND REGIONAL DYSFUNCTION [J].
SECHTEM, U ;
SOMMERHOFF, BA ;
MARKIEWICZ, W ;
WHITE, RD ;
CHEITLIN, MD ;
HIGGINS, CB .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (01) :145-151
[28]  
SHEEHAN F, 1996, MARCUS CARDIAC IMAGI, P164
[29]  
Sheehan F. H., 1983, Computers in Cardiology. Ninth Meeting of Computers in Cardiology, P97
[30]   PROGNOSTIC-SIGNIFICANCE OF REGIONAL WALL MOTION ABNORMALITY IN PATIENTS WITH PRIOR MYOCARDIAL-INFARCTION - A PROSPECTIVE CORRELATIVE STUDY OF 2-DIMENSIONAL ECHOCARDIOGRAPHY AND ANGIOGRAPHY [J].
SHIINA, A ;
TAJIK, AJ ;
SMITH, HC ;
LENGYEL, M ;
SEWARD, JB .
MAYO CLINIC PROCEEDINGS, 1986, 61 (04) :254-262