Manganese dioxide graphite composite electrodes: Application to the electroanalysis of hydrogen peroxide, ascorbic acid and nitrite

被引:62
作者
Langley, Cathryn E. [1 ]
Sljukic, Biljana [1 ]
Banks, Craig E. [1 ]
Compton, Richard G. [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
D O I
10.2116/analsci.23.165
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The modification of carbon powder with manganese dioxide using a wet impregnation procedure with electrochemical characterisation of the modified powder is described. The process involves saturation of the carbon powder with manganese(II) nitrate followed by thermal treatment at ca. 773 K leading to formation of manganese(IV) oxide on the surface of the carbon powder. The construction of composite electrodes based on manganese dioxide modified carbon powder and epoxy resin is also described, including optimisation of the percentage of the modified carbon powder. Composite electrodes showed attractive performances for electroanalytical applications, proving to be suitable for the electrochemical detection of hydrogen peroxide, ascorbic acid and nitrite ions with limits of detection comparable to the detection limits achieved by other analytical techniques. The results obtained for detection of these analytes, together with composite electrodes flexible design and low cost offers potential application of composite electrodes in biosensors.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 67 条
[1]   Electrocatalytic activity of Ce(III)-EDTA complex toward the oxidation of nitrite ion [J].
Abbaspour, A ;
Mehrgardi, MA .
TALANTA, 2005, 67 (03) :579-584
[2]   Configurations used in the design of screen-printed enzymatic biosensors.: A review [J].
Albareda-Sirvent, M ;
Merkoçi, A ;
Alegret, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (1-2) :153-163
[3]   Iron(II) phthalocyanine-modified carbon-paste electrode for potentiometric detection of ascorbic acid [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S ;
Mirkhani, V .
ANALYTICAL BIOCHEMISTRY, 2001, 290 (02) :277-282
[4]  
Ammundsen B, 2001, ADV MATER, V13, P943, DOI 10.1002/1521-4095(200107)13:12/13<943::AID-ADMA943>3.0.CO
[5]  
2-J
[6]   An assay for ascorbic acid based on polyaniline-coated microplates [J].
Bossi, A ;
Piletsky, SA ;
Piletska, EV ;
Righetti, PG ;
Turner, APF .
ANALYTICAL CHEMISTRY, 2000, 72 (18) :4296-4300
[7]   Tetraalkylammonium manganese oxide gels: Preparation, structure, and ion-exchange properties [J].
Brock, SL ;
Sanabria, M ;
Nair, J ;
Suib, SL ;
Ressler, T .
JOURNAL OF PHYSICAL CHEMISTRY B, 2001, 105 (23) :5404-5410
[8]   HIGHLY EFFICIENT HETEROGENEOUS PHOTOOXIDATION OF 2-PROPANOL TO ACETONE WITH AMORPHOUS MANGANESE OXIDE CATALYSTS [J].
CAO, H ;
SUIB, SL .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (12) :5334-5342
[9]   Flow injection amperometric detection of ascorbic acid using a Prussian Blue film-modified electrode [J].
Castro, SSL ;
Balbo, VR ;
Barbeira, PJS ;
Stradiotto, NR .
TALANTA, 2001, 55 (02) :249-254
[10]   OXIDATIVE FLOW-INJECTION AMPEROMETRIC DETERMINATION OF NITRITE AT AN ELECTROCHEMICALLY PRE-TREATED GLASSY-CARBON ELECTRODE [J].
CHAMSI, AY ;
FOGG, AG .
ANALYST, 1988, 113 (11) :1723-1727