Sustentacular screw placement with guidance during ORIF of calcaneal fracture: an anatomical specimen study

被引:15
作者
Wang, Chen [1 ]
Huang, Dichao [1 ]
Ma, Xin [1 ]
Wang, Xu [1 ]
Huang, Jiazhang [1 ]
Zhang, Chao [1 ]
Chen, Li [1 ]
Geng, Xiang [1 ]
机构
[1] Fudan Univ, Huashan Hosp, Dept Orthoped, 12 Middle Wulumuqi Rd, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Calcaneal fracture; Assistant of guidance; Sustentacular screw; ORIF; Accuracy; FIXATION; TALI;
D O I
10.1186/s13018-017-0580-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: The sustentacular screw is essential to maintain the stability of the subtalar joint during ORIF (open reduction with internal fixation) of calcaneal fractures. Currently, the screw is still inserted based on surgeons' anatomical experiences and nearly 40% of screws are misplaced from the sustentaculum. Previous studies demonstrated some methods of sustentacular screw placement through anatomical measurements or navigation system. The purposes of this study are to design an assistant guidance device that can effectively improve the accuracy of sustentacular screw placement and to compare the accuracy of this technique with traditional screw placement based on experience. Methods: A customized guidance device is designed, aiming to improve the accuracy of sustentacular screw placement. Twenty cadaveric specimens are used in the present study. Ten specimens are allocated into the guidance-assisted group, and others are included in the traditional screw insertion group. A total of 40 sustentacular screw placements are performed in each group. Fluoroscopic images are obtained after each screw placement. Only the screw that captures the sustentaculum both on the lateral and axial X-ray views was regarded as an accurate placement. Results: The accuracy rate in the guidance-assisted group is 87.5% (35 out of 40 times of insertions) while in the traditional screw insertion group, the accuracy rate is 65% (26 out of 40 times of insertions). A significant difference is found between the two groups (p = 0.018). Conclusions: The guidance-assisted technique is a convenient approach that can effectively improve the accuracy of sustentacular screw placement during the ORIF of calcaneal fractures. This study provides a novel technique that significantly facilitates sustentacular screw insertion and improves its accuracy.
引用
收藏
页数:6
相关论文
共 20 条
[1]
Operative compared with nonoperative treatment of displacedintra-articular calcaneal fractures - A prospective, randomized, controlled multicenter trial [J].
Buckley, R ;
Tough, S ;
McCormack, R ;
Pate, G ;
Leighton, R ;
Petrie, D ;
Galpin, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1733-1744
[2]
Screw Placement Relative to the Calcaneal Fracture Constant Fragment: An Anatomic Study [J].
Bussewitz, Bradly W. ;
Hyer, Christopher F. .
Journal of Foot & Ankle Surgery, 2015, 54 (03) :392-394
[3]
Displaced intra-articular calcaneal fractures - Variables predicting late subtalar fusion [J].
Csizy, M ;
Buckley, R ;
Tough, S ;
Leighton, R ;
Smith, J ;
McCormack, R ;
Pate, G ;
Petrie, D ;
Galpin, R .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (02) :106-112
[4]
Fractures of the sustentaculum tali [J].
Duerr, C. ;
Zwipp, H. ;
Rammelt, S. .
OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2013, 25 (06) :569-578
[5]
Intraoperative 3D Imaging in Calcaneal Fracture Care-Clinical Implications and Decision Making [J].
Geerling, Jens ;
Kendoff, Daniel ;
Citak, Musa ;
Zech, Stefan ;
Gardner, Michael J. ;
Huefner, Tobias ;
Krettek, Christian ;
Richter, Martinus .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (03) :768-773
[6]
Assessing Accuracy of Sustentaculum Screw Placement During Calcaneal Fixation [J].
Gitajn, I. Leah ;
Toussaint, Rull James ;
Kwon, John Y. .
FOOT & ANKLE INTERNATIONAL, 2013, 34 (02) :282-286
[7]
Current Controversies in Management of Calcaneus Fractures [J].
Gotha, Heather E. ;
Zide, Jacob R. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2017, 48 (01) :99-+
[8]
Sustentaculum Tali Screw Placement for Calcaneus Fractures - Different Navigation Procedures Compared to the Conventional Technique [J].
Gras, F. ;
Marintschev, I. ;
Wilharm, A. ;
Lindner, R. ;
Klos, K. ;
Mueckley, T. ;
Hofmann, G. O. .
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2010, 148 (03) :309-318
[9]
Lin PP, 1998, CLIN ORTHOP RELAT R, P194
[10]
NONUNION OF A FRACTURE OF THE SUSTENTACULUM TALL CAUSING A TARSAL TUNNEL-SYNDROME - A CASE-REPORT [J].
MYERSON, MS ;
BERGER, BI .
FOOT & ANKLE INTERNATIONAL, 1995, 16 (11) :740-742