Imaging ultrasonometry of the calcaneus: Dependence on calcaneal area

被引:5
作者
Damilakis, J [1 ]
Perisinakis, K [1 ]
Gourtsoyiannis, N [1 ]
机构
[1] Univ Crete, Fac Med, GR-71409 Iraklion, Crete, Greece
关键词
osteoporosis; broadband ultrasound attenuation; speed of sound; calcaneus; calcaneal area;
D O I
10.1007/s00223001091
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The purpose of this study was (1) to investigate the dependence of broadband ultrasound attenuation (BUA) and speed of sound (SOS) measured in a circular region of interest (ROI) having a fixed size on calcaneal area and (2) to examine whether the normalization of ultrasonic variables for the area of the calcaneus provides better differentiation of diseased subjects from healthy individuals. Ultrasound variables were estimated in 169 healthy postmenopausal women (mean age 66.5 years, range 42-87 years) and 39 women with vertebral fractures (mean age 72.9 years, range 51-86 years). A minimum attenuation ROI, 15 mm in diameter, with a commercial imaging ultrasonometer was used. Significant relationships were found between both ultrasonic variables and calcaneal area (r(2) = 0.06, P < 0.001 for BUA, r(2) = 0.12, P < 0.0001 for SOS). Normalization of ultrasound variables (BUAn and SOSn) was based on the regression equations of the relationships among BUA, SOS, and calcaneal area. In a precision study, nine women were examined five times each to determine the errors arising from both the repositioning of the foot and selection of the calcaneal area. The reproducibility errors of BUA. SOS, BUAn, SOSn, and area were 0.87%, 0.20%, 1.07%, 0.27%, and 3.72%, respectively. Significant differences were found between the areas under the ROC curve for BUAn and BUA (area under the curve = 0.93 for BUAn versus 0.90 for BUA, P = 0.003) as well as for SOSn and SOS (area under the curve = 0.85 for SOSn versus 0.79 for SOS, P = 0.003). Normalization of ultrasound variables for calcaneal area improves the discrimination of clinical studies.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 12 条
[1]
Camacho FJF, 1996, J ANAT, V189, P205
[2]
Effect of region of interest location on ultrasound measurements of the calcaneus [J].
Damilakis, J ;
Perisinakis, K ;
Vagios, E ;
Tsinikas, D ;
Gourtsoyiannis, N .
CALCIFIED TISSUE INTERNATIONAL, 1998, 63 (04) :300-305
[3]
Effect of lifetime occupational physical activity on indices of bone mineral status in healthy postmenopausal women [J].
Damilakis, J ;
Perisinakis, K ;
Kontakis, G ;
Vagios, E ;
Gourtsoyiannis, N .
CALCIFIED TISSUE INTERNATIONAL, 1999, 64 (02) :112-116
[4]
QUANTITATIVE ULTRASOUND OF THE HEEL - CORRELATION WITH DENSITOMETRIC MEASUREMENTS AT DIFFERENT SKELETAL SITES [J].
FAULKNER, KG ;
MCCLUNG, MR ;
COLEMAN, LJ ;
KINGSTONSANDAHL, E .
OSTEOPOROSIS INTERNATIONAL, 1994, 4 (01) :42-47
[5]
Quantitative ultrasound imaging at the calcaneus using an automatic region of interest [J].
Fournier, B ;
Chappard, C ;
Roux, C ;
Berger, G ;
Laugier, P .
OSTEOPOROSIS INTERNATIONAL, 1997, 7 (04) :363-369
[6]
GALLAGHER JC, 1988, BONE MINER, V4, P189
[7]
ULTRASOUND ATTENUATION IMAGING IN THE OS CALCIS - AN IMPROVED METHOD [J].
LAUGIER, P ;
BERGER, G ;
GIAT, P ;
BONNINFAYET, P ;
LAVALJEANTET, M .
ULTRASONIC IMAGING, 1994, 16 (02) :65-76
[8]
BROAD-BAND ULTRASONIC-ATTENUATION IMAGING - A NEW IMAGING TECHNIQUE OF THE OS CALCIS [J].
LAUGIER, P ;
GIAT, P ;
BERGER, G .
CALCIFIED TISSUE INTERNATIONAL, 1994, 54 (02) :83-86
[9]
PRELIMINARY EVALUATION OF A NEW ULTRASOUND BONE DENSITOMETER [J].
LEES, B ;
STEVENSON, JC .
CALCIFIED TISSUE INTERNATIONAL, 1993, 53 (03) :149-152
[10]
Automatic detection of the boundary of the calcaneus from ultrasound parametric images using an active contour model; Clinical assessment [J].
Lefebvre, F ;
Berger, G ;
Laugier, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (01) :45-52