Optical Doppler velocimetry at various retinal vessel depths by variation of the source coherence length

被引:16
作者
Logean, E
Schmetterer, LF
Riva, CE
机构
[1] Inst Rech Ophtalmol, CH-1950 Sion 4, Switzerland
[2] Univ Lausanne, Fac Med, Lausanne, Switzerland
[3] Univ Vienna, Dept Clin Pharmacol, A-1090 Vienna, Austria
[4] Univ Vienna, Inst Med Phys, A-1090 Vienna, Austria
关键词
D O I
10.1364/AO.39.002858
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report on what we believe is a novel approach to measuring the velocity of red blood cells (RBC's) at different depths of retinal. vessels by use of low-coherence sources. The technique, variable coherence optical Doppler velocimetry (VCODV), performs Doppler shift measurements through autodyne mixing between the Light scattered by the RBC's and by the vessel front wall (reference). Only the light from RBC's moving at a depth less than half the coherence length (CL) mixes efficiently with the reference. Measurements of the Doppler shifts from RBC's with sources of four different CL's in a 152-mu m vein of a volunteer confirmed the feasibility of VCODV. This approach has the potential to monitor in vivo retinal RBC velocity gradient at the vessel wall and the velocity profile within the blood vessel in the condition of symmetric blood flow profiles. (C) 2000 Optical Society of America OCIS codes: 170.3340, 030.1640, 170.0170, 170.4470.
引用
收藏
页码:2858 / 2862
页数:5
相关论文
共 20 条
[1]   Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography [J].
Chen, ZP ;
Milner, TE ;
Srinivas, S ;
Wang, XJ ;
Malekafzali, A ;
vanGemert, MJC ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (14) :1119-1121
[2]   THE INFLUENCE OF MECHANICAL FORCES AND FLOW MECHANISMS ON VESSEL OCCLUSION [J].
FANKHAUSER, F ;
BEBIE, H ;
KWASNIEWSKA, S .
LASERS IN SURGERY AND MEDICINE, 1987, 6 (06) :530-532
[3]   LASER DOPPLER TECHNIQUE FOR ABSOLUTE MEASUREMENT OF BLOOD SPEED IN RETINAL-VESSELS [J].
FEKE, GT ;
GOGER, DG ;
TAGAWA, H ;
DELORI, FC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (09) :673-680
[4]   LASER DOPPLER MEASUREMENTS OF BLOOD VELOCITY IN HUMAN RETINAL-VESSELS [J].
FEKE, GT ;
RIVA, CE .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (04) :526-531
[5]  
GRUNWALD JE, 1994, LASER DOPPLER, P223
[6]   In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomograghy [J].
Izatt, JA ;
Kulkami, MD ;
Yazdanfar, S ;
Barton, JK ;
Welch, AJ .
OPTICS LETTERS, 1997, 22 (18) :1439-1441
[7]   Accuracy and noise in optical Doppler tomography studied by Monte Carlo simulation [J].
Lindmo, T ;
Smithies, DJ ;
Chen, ZP ;
Nelson, JS ;
Milner, TE .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :3045-3064
[8]   The study of the influence of flow on vascular endothelial biology [J].
Nerem, RM ;
Alexander, RW ;
Chappell, DC ;
Medford, RM ;
Varner, SE ;
Taylor, WR .
AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1998, 316 (03) :169-175
[9]   RETINAL LASER DOPPLER VELOCIMETRY - TOWARD ITS COMPUTER-ASSISTED CLINICAL USE [J].
PETRIG, BL ;
RIVA, CE .
APPLIED OPTICS, 1988, 27 (06) :1126-1134
[10]  
Petrig BL, 1995, OCULAR BLOOD FLOW, P120