Description and implementation of a quality control program in an imaging-based clinical trial

被引:51
作者
Cagnon, Christopher H.
Cody, Dianna D.
McNitt-Gray, Michael F.
Seibert, J. Anthony
Judy, Philip F.
Aberle, Denise R.
机构
[1] Univ Calif Los Angeles, Daivd Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[2] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
[3] Univ Calif Davis, Med Ctr, Dept Radiol, Davis, CA 95616 USA
[4] Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
lung cancer screening; standardizing CT protocols; quality control in imaging based clinical trials;
D O I
10.1016/j.acra.2006.08.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The American College of Radiology Imaging Network is participating in the National Lung Screening Trial, a large, multicenter, randomized controlled trial, comparing multidetector helical computed tomography (MDCT) versus chest radiography (CXR) in screening for lung cancer. Because the threshold for detection of disease is an inherent function of image quality, and consistent image quality is necessary to track changes in suspicious findings, our purpose was to develop an image quality control (QC) program across all clinical sites for both modalities. Materials and Methods. The primary goals of the QC program include standardization of imaging protocols, certification of imaging equipment, and ongoing, periodic evaluation of the equipment calibration and image quality. Minimum standards for equipment and standardized cross-platform acquisition protocols are achieved via radiologist and physicist attestation forms and web-distributed technique charts, respectively. Imaging equipment performance standards are implemented through an initial machine certification process that includes equipment calibration. Ongoing assessment of equipment performance and calibration, as well as adherence to established imaging protocols. is accomplished via periodic submission of calibration records and phantom images. Participant-specific image acquisition parameters are entered into a web-based centralized database and variations from established protocols are automatically flagged for review. Participant radiation dose can be estimated from the image acquisition parameters applied to the imaging equipment calibration measurements. A radiologist visual review committee also evaluates participant images for diagnostic quality. Data are collected from 23 independent centers, representing 14 models of MDCT scanners from four manufacturers, and CXR systems that include film-screen, computed radiography, and direct digital radiography systems. Results. Widespread imaging protocol variation in extant clinical practice-as well as variability in equipment technology, image acquisition parameters, manufacturer terminology, and user interface-have required careful standardization as a prerequisite to trial participation and ongoing image QC. Acceptable ranges for image acquisition parameters have been refined to accommodate continuously evolving equipment platforms and the scope of participant size and body habitus. Conclusion. Standardization of imaging protocols is a critical component of image-based clinical trials, predicated on ongoing dialogue between sites and a centralized review committee.
引用
收藏
页码:1431 / 1441
页数:11
相关论文
共 13 条
  • [1] Epidemiology of lung cancer: Looking to the future
    Alberg, AJ
    Brock, MV
    Samet, JM
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (14) : 3175 - 3185
  • [2] [Anonymous], ACR PRACT GUID PERF
  • [3] A PRACTICAL METHOD TO MEASURE THE MTF OF CT SCANNERS
    DROEGE, RT
    MORIN, RL
    [J]. MEDICAL PHYSICS, 1982, 9 (05) : 758 - 759
  • [4] Early Lung Cancer Action Project: overall design and findings from baseline screening
    Henschke, CI
    McCauley, DI
    Yankelevitz, DF
    Naidich, DP
    McGuinness, G
    Miettinen, OS
    Libby, DM
    Pasmantier, MW
    Koizumi, J
    Altorki, NK
    Smith, JP
    [J]. LANCET, 1999, 354 (9173) : 99 - 105
  • [5] Dosimetry for optimisation of patient protection in computed tomography
    Jessen, KA
    Shrimpton, PC
    Geleijns, J
    Panzer, W
    Tosi, G
    [J]. APPLIED RADIATION AND ISOTOPES, 1999, 50 (01) : 165 - 172
  • [6] The phantom portion of the American College of Radiology (ACR) Computed Tomography (CT) accreditation program: Practical tips, artifact examples, and pitfalls to avoid
    McCollough, CH
    Bruesewitz, MR
    McNitt-Gray, MF
    Bush, K
    Ruckdeschel, T
    Payne, JT
    Brink, JA
    Zeman, RK
    [J]. MEDICAL PHYSICS, 2004, 31 (09) : 2423 - 2442
  • [7] Calculation of effective dose
    McCollough, CH
    Schueler, BA
    [J]. MEDICAL PHYSICS, 2000, 27 (05) : 828 - 837
  • [8] Radiation issues in computed tomography screening
    McNitt-Gray, MF
    [J]. SEMINARS IN ROENTGENOLOGY, 2003, 38 (01) : 87 - 99
  • [9] AAPM/RSNA physics tutorial for residents:: Topics in CT -: Radiation dose in CT1
    McNitt-Gray, MF
    [J]. RADIOGRAPHICS, 2002, 22 (06) : 1541 - 1553
  • [10] *NAT EL MAN ASS, 2004, DICOM CORR IT