Noninvasive, transthoracic, low-frequency ultrasound augments thrombolysis in a canine model of acute myocardial infarction

被引:77
作者
Siegel, RJ [1 ]
Atar, S [1 ]
Fishbein, MC [1 ]
Brasch, AV [1 ]
Peterson, TM [1 ]
Nagai, T [1 ]
Pal, D [1 ]
Nishioka, T [1 ]
Chae, JS [1 ]
Birnbaum, Y [1 ]
Zanelli, C [1 ]
Luo, H [1 ]
机构
[1] Cedars Sinai Med Ctr, Div Cardiol, Dept Med, Los Angeles, CA 90048 USA
关键词
thrombolysis; myocardial infarction; ultrasonics; fibrinolysis;
D O I
10.1161/01.CIR.101.17.2026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Limitations of coronary thrombolysis include the time to reperfusion, patency rate, and bleeding. We evaluated the use of noninvasive transcutaneous ultrasound to augment coronary thrombolysis. Methods and Results-In 24 dogs, a thrombotic occlusion of the left anterior descending coronary artery was induced and documented by 12-lead ECG and coronary angiography. After greater than or equal to 60 minutes of occlusion, tissue-type plasminogen activator (t-PA; 1.42 mg/kg) was given intravenously over 90 minutes. A total of 12 of the 24 dogs had concomitant transcutaneous application of low-frequency ultrasound (27 kHz) over the chest. At 90 minutes, the mean TIMI grade flow in the t-PA alone group was 0.92+/-1.4 compared with 2.42+/-1.9 in the t-PA plus ultrasound group (P=0.006). TIMI 2 to 3 flow was present in 4 of 12 cases receiving t-PA alone compared with 10 of 12 cases receiving t-PA plus ultrasound (P=0.003). At 180 minutes, mean TIMI grade flow was 0.75+/-1.4 in the t-PA alone group versus 2.58+/-0.9 in the t-PA plus ultrasound group (P=0.001). Pathological examination confirmed the angiographic patency rate and did not reveal injury secondary to ultrasound in the skin, soft tissues, heart, or lungs. Conclusions-In vivo, the noninvasive transthoracic application of low-frequency ultrasound (1) greatly augments the efficacy of t-PA-mediated thrombolysis, (2) seems safe, and (3) has substantial potential as a noninvasive adjunct to improve coronary patency without increasing the risk of bleeding.
引用
收藏
页码:2026 / 2029
页数:4
相关论文
共 12 条
[11]   Enhancement of fibrinolysis with 40-kHz ultrasound [J].
Suchkova, V ;
Siddiqi, FN ;
Carstensen, EL ;
Dalecki, D ;
Child, S ;
Francis, CW .
CIRCULATION, 1998, 98 (10) :1030-1035
[12]   Thrombolysis for acute myocardial infarction [J].
White, HD ;
Van de Werf, FJJ .
CIRCULATION, 1998, 97 (16) :1632-1646