Optimizing the beam pattern of a forward-viewing ring-annular ultrasound array for intravascular imaging

被引:59
作者
Wang, Y [1 ]
Stephens, DN
O'Donnell, M
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Jomed Inc, Rancho Cordova, CA USA
关键词
D O I
10.1109/TUFFC.2002.1159845
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Intravascular ultrasound (IVUS) imaging systems using circumferential arrays mounted on cardiac catheter tips fire beams orthogonal to the principal axis of the catheter. The system produces high resolution cross-sectional images but must be guided by conventional angioscopy. A real-time forward-viewing array, integrated into the same catheter, could greatly reduce radiation exposure by decreasing angiographic guidance. Unfortunately, the mounting requirement of a catheter guide wire prohibits a full-disk imaging aperture. Given only an annulus of array elements, prior theoretical investigations have only considered a circular ring of point transceivers and focusing strategies using all elements in the highly dense array, both impractical assumptions. In this paper, we consider a practical array geometry and signal processing architecture for a forward-viewing IVUS system. Our specific design uses a total of 210 transceiver firings with synthetic reconstruction for a given 3-D image frame. Simulation results demonstrate this design can achieve side-lobes under -40 dB for on-axis situations and under -30 dB for steering to the edge of a 60degrees cone.
引用
收藏
页码:1652 / 1664
页数:13
相关论文
共 29 条
[1]  
BACK MR, 1994, AM SURGEON, V60, P738
[2]   Broad-bandwidth radiation patterns of sparse two-dimensional vernier arrays [J].
Brunke, SS ;
Lockwood, GR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (05) :1101-1109
[3]   Modified weighting method for forward-looking ring-annular arrays [J].
Crowe, JR ;
Hamilton, JD ;
Stephens, DN ;
Wang, Y ;
O'Donnell, M .
ULTRASONIC IMAGING, 2001, 23 (01) :19-38
[4]   ARTERIAL IMAGING WITH A NEW FORWARD-VIEWING INTRAVASCULAR ULTRASOUND CATHETER .1. INITIAL STUDIES [J].
EVANS, JL ;
NG, KH ;
VONESH, MJ ;
KRAMER, BL ;
MEYERS, SN ;
MILLS, TA ;
KANE, BJ ;
ALDRICH, WN ;
JANG, YT ;
YOCK, PG ;
ROLD, MD ;
ROTH, SI ;
MCPHERSON, DD .
CIRCULATION, 1994, 89 (02) :712-717
[5]  
GILL PE, 1981, PRACTICAL OPTIMIZATI, P7
[6]   THE UNIFYING ROLE OF THE COARRAY IN APERTURE SYNTHESIS FOR COHERENT AND INCOHERENT IMAGING [J].
HOCTOR, RT ;
KASSAM, SA .
PROCEEDINGS OF THE IEEE, 1990, 78 (04) :735-752
[7]  
KARAMAN M, 1994, ULTRASON, P1543, DOI 10.1109/ULTSYM.1994.401885
[8]  
Liang David H., 1997, Biomedical Instrumentation and Technology, V31, P45
[9]  
LIGHT ED, 1999, P SPIE C ULTR TRANSD, P76
[10]  
Lim J.S., 1990, 2 DIMENSIONAL SIGNAL, P1