Blood flow and vessel mechanics in a physiologically realistic model of a human carotid arterial bifurcation

被引:235
作者
Zhao, SZ [1 ]
Xu, XY
Hughes, AD
Thom, SA
Stanton, AV
Ariff, B
Long, Q
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Chem Engn & Chem Technol, London SW7 2AZ, England
[2] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, London W2 1NY, England
基金
英国工程与自然科学研究理事会;
关键词
carotid bifurcation; coupled fluid/solid model; in vivo data;
D O I
10.1016/S0021-9290(00)00043-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The pulsatile flow in an anatomically realistic compliant human carotid bifurcation was simulated numerically. Pressure and mass flow waveforms in the carotid arteries were obtained from an individual subject using non-invasive techniques. The geometry of the computational model was reconstructed from magnetic resonance angiograms. Maps of time-average wall shear stress, contours of velocity in the flow field as well as wall movement and tensile stress on the arterial wall are all presented. Inconsistent with previous findings from idealised geometry models, flow in the carotid sinus is dominated by a strong helical flow accompanied by a single secondary vortex motion. This type of flow is induced primarily by the asymmetry and curvature of the in vivo geometry. Flow simulations have been carried out under the rigid wall assumption and for the compliant wall, respectively. Comparison of the results demonstrates the quantitative influence of the vessel wall motion. Generally there is a reduction in the magnitude of wall shear stress, with its degree depending on location and phase of the cardiac cycle. The region of slow or reversed flow was greater, in both spatial and temporal terms in the compliant model, but the global. characteristics of the flow and stress patterns remain unchanged. The analysis of mechanical stresses on the vessel surface shows a complicated stress field. Stress concentration occurs at both the anterior and posterior aspects of the proximal internal bulb. These are also regions of low wall shear stress. The comparison of computed and measured wall movement generally shows good agreement. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:975 / 984
页数:10
相关论文
共 34 条
[21]   Magnetic resonance image processing and structured grid generation of a human abdominal bifurcation [J].
Long, Q ;
Xu, XY ;
Collins, MW ;
Bourne, M ;
Griffith, TM .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1998, 56 (03) :249-259
[22]   Hemodynamics of human carotid artery bifurcations: Computational studies with models reconstructed from magnetic resonance imaging of normal subjects [J].
Milner, JS ;
Moore, JA ;
Rutt, BK ;
Steinman, DA .
JOURNAL OF VASCULAR SURGERY, 1998, 28 (01) :143-156
[23]   Accuracy of computational hemodynamics in complex arterial geometries reconstructed from magnetic resonance imaging [J].
Moore, JA ;
Steinman, DA ;
Holdsworth, DW ;
Ethier, CR .
ANNALS OF BIOMEDICAL ENGINEERING, 1999, 27 (01) :32-41
[24]  
Pedley T.J., 1980, The fluid mechanics of large blood vessels
[25]  
Perktold K, 1998, J BIOMECH, V31, P217, DOI 10.1016/S0021-9290(97)00118-8
[26]   COMPUTER-SIMULATION OF LOCAL BLOOD-FLOW AND VESSEL MECHANICS IN A COMPLIANT CAROTID-ARTERY BIFURCATION MODEL [J].
PERKTOLD, K ;
RAPPITSCH, G .
JOURNAL OF BIOMECHANICS, 1995, 28 (07) :845-856
[27]   NUMERICAL FLOW STUDIES IN HUMAN CAROTID-ARTERY BIFURCATIONS - BASIC DISCUSSION OF THE GEOMETRIC FACTOR IN ATHEROGENESIS [J].
PERKTOLD, K ;
RESCH, M .
JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (02) :111-123
[28]  
PERKTOLD K, 1991, ASME, V113, P464
[29]   HEMODYNAMIC FORCES ARE COMPLEX REGULATORS OF ENDOTHELIAL GENE-EXPRESSION [J].
RESNICK, N ;
GIMBRONE, MA .
FASEB JOURNAL, 1995, 9 (10) :874-882
[30]   THE PATHOGENESIS OF ATHEROSCLEROSIS - A PERSPECTIVE FOR THE 1990S [J].
ROSS, R .
NATURE, 1993, 362 (6423) :801-809