Inadequacy of qualitative implantable cardioverter defibrillator electrogram analysis to distinguish supraventricular from ventricular tachycardia due to electrogram changes during normally conducted complexes

被引:5
作者
Hallett, N
Monahan, K
Casavant, D
Epstein, L
Josephson, M
机构
[1] BETH ISRAEL HOSP,ARRHYTHMIA SERV,BOSTON,MA 02215
[2] HARVARD THORNDIKE ELECTROPHYSIOL INST,BOSTON,MA
[3] MEDTRONIC INC,MINNEAPOLIS,MN
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1997年 / 20卷 / 06期
关键词
electrograms; ICD therapy; ventricular and supraventricular tachycardia;
D O I
10.1111/j.1540-8159.1997.tb03548.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Stored electrograms (EGMs) recorded from ICD leads are used to evaluate the appropriateness of ICD therapies. Stored EGMs different from sinus have been interpreted as ventricular in origin. We present a patient with an ICD for VT who received multiple shocks for a tachycardia with a stored EGM different than sin us, suggesting VT. An electrophysiological study demonstrated EGMs different than sinus during atrial pacing and induced supraventricular arrhythmias. This case points out the limitations of stored EGMs and suggests complete electrophysiological study with analysis of EGMs during induced arrhythmias should be performed prior to discharge.
引用
收藏
页码:1723 / 1726
页数:4
相关论文
共 7 条
[1]   USE OF BIPOLAR RECORDINGS FROM PATCH-PATCH AND RATE SENSING LEADS TO DISTINGUISH VENTRICULAR-TACHYCARDIA FROM SUPRAVENTRICULAR RHYTHMS IN PATIENTS WITH IMPLANTABLE CARDIOVERTER DEFIBRILLATORS [J].
CALLANS, DJ ;
HOOK, BG ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11) :1917-1922
[2]   PACED BEATS FOLLOWING SINGLE NONSENSED COMPLEXES IN A CODEPENDENT CARDIOVERTER DEFIBRILLATOR AND BRADYCARDIA PACING SYSTEM - POTENTIAL FOR VENTRICULAR-TACHYCARDIA INDUCTION [J].
CALLANS, DJ ;
HOOK, BG ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (08) :1281-1287
[3]   DETECTION OF PATHOLOGICAL TACHYCARDIA BY ANALYSIS OF ELECTROGRAM MORPHOLOGY [J].
DAVIES, DW ;
WAINWRIGHT, RJ ;
TOOLEY, MA ;
LLOYD, D ;
NATHAN, AW ;
SPURRELL, RAJ ;
CAMM, AJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (02) :200-208
[4]   IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR THERAPY IN THE ABSENCE OF SIGNIFICANT SYMPTOMS - RHYTHM DIAGNOSIS AND MANAGEMENT AIDED BY STORED ELECTROGRAM ANALYSIS [J].
HOOK, BG ;
CALLANS, DJ ;
KLEIMAN, RB ;
FLORES, BT ;
MARCHLINSKI, FE .
CIRCULATION, 1993, 87 (06) :1897-1906
[5]   IDENTIFICATION OF VENTRICULAR-TACHYCARDIA WITH USE OF THE MORPHOLOGY OF THE ENDOCARDIAL ELECTROGRAM [J].
LANGBERG, JJ ;
GIBB, WJ ;
AUSLANDER, DM ;
GRIFFIN, JC .
CIRCULATION, 1988, 77 (06) :1363-1369
[6]   ICD DATA-STORAGE - VALUE IN ARRHYTHMIA MANAGEMENT [J].
MARCHLINSKI, FE ;
GOTTLIEB, CD ;
SARTER, B ;
FINKLE, J ;
HOOK, B ;
CALLANS, D ;
SCHWARTZMAN, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (03) :527-534
[7]   Effect of bundle branch block on local electrogram morphologic features: Implications for arrhythmia diagnosis by stored electrogram analysis [J].
Sarter, BH ;
Hook, BG ;
Callans, DJ ;
Marchlinski, FE .
AMERICAN HEART JOURNAL, 1996, 131 (05) :947-952