Intracranial venous system: Gadolinium-enhanced three-dimensional MR venography with auto-trigered elliptic centric-ordered sequence - Initial experience

被引:97
作者
Farb, RI
Scott, JN
Willinsky, RA
Montanera, W
Wright, GA
terBrugge, KG
机构
[1] Univ Toronto, Toronto Western Hosp, Dept Med Imaging, Div Neuroradiol, Toronto, ON M5T 2S8, Canada
[2] Sunnybrook & Womens Coll Hlth Sci Ctr, Dept Imaging Res, Toronto, ON, Canada
关键词
cerebral blood vessels; MR; magnetic resonance (MR); technology; vascular studies;
D O I
10.1148/radiol.2261020670
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate gadolinium-enhanced three-dimensional auto-triggered elliptic centric-ordered (ATECO) magnetic resonance (MR) venography for imaging of the intracranial venous system. MATERIALS AND METHODS: ATECO MR venography was performed in 23 patients, eight of whom also underwent two-dimensional time-of-flight (TOF) MR venography for imaging of the intracranial venous system. Seventeen predefined venous structures were evaluated on all venograms by two neuroradiologists. Visualization of venous structures was defined as completely visible (including clearly pathologic), partially visible, or not visible. Readers were also asked to compare the visibility of these predefined structures on ATECO and TOF MR venograms, where available. RESULTS: Of the 23 patients, six had dural venous sinus disease. Of the remaining 17 healthy patients, five underwent both ATECO and TOF MR venography and 12 underwent ATECO MR venography alone. On ATECO MR venograms obtained in the healthy patients, visibility of the 17 predefined venous structures was complete in 92% (531 of 578) of evaluations. For the five normal TOF MR venograms, the rate of complete visibility of the same venous structures was 61% (104 of 170). The rate of complete visibility of the large dural venous sinuses was 99% for ATECO MR venograms and 75% for TOF MR venograms. CONCLUSION: ATECO MR venography provides high-quality images of the intracranial venous anatomy and was superior to TOF MR venography for consistent complete visibility of venous structures. (C) RSNA, 2002.
引用
收藏
页码:203 / 209
页数:7
相关论文
共 15 条
[1]  
Ayanzen RH, 2000, AM J NEURORADIOL, V21, P74
[2]  
DERBYSHIRE JA, 1998, P INT SOC MAGN RES M, P766
[3]   High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: A prospective comparison with digital subtraction angiography [J].
Fain, SB ;
King, BF ;
Breen, JF ;
Kruger, DG ;
Riederer, SJ .
RADIOLOGY, 2001, 218 (02) :481-490
[4]   Intracranial arteriovenous malformations: Real-time auto-triggered elliptic centric-ordered 3D gadolinium-enhanced MR angiography - Initial assessment [J].
Farb, RI ;
McGregor, C ;
Kim, JK ;
Laliberte, M ;
Derbyshire, JA ;
Willinsky, RA ;
Cooper, PW ;
Westman, DG ;
Cheung, G ;
Schwartz, ML ;
Stainsby, JA ;
Wright, GA .
RADIOLOGY, 2001, 220 (01) :244-251
[5]   Spinal dural arteriovenous fistula localization with a technique of first-pass gadolinium-enhanced MR angiography: Initial experience [J].
Farb, RI ;
Kim, JK ;
Willinsky, RA ;
Montanera, WJ ;
terBrugge, K ;
Derbyshire, JA ;
van Dijk, JMC ;
Wright, GA .
RADIOLOGY, 2002, 222 (03) :843-850
[6]  
Huston J, 2001, RADIOLOGY, V218, P138
[7]  
Liang LX, 2001, AM J NEURORADIOL, V22, P481
[8]   MR angiography of the intracranial venous system [J].
Liauw, L ;
van Buchem, MA ;
Spilt, A ;
de Bruïne, FT ;
van den Berg, R ;
Hermans, J ;
Wasser, MNJM .
RADIOLOGY, 2000, 214 (03) :678-682
[9]   The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality [J].
Maki, JH ;
Prince, MR ;
Londy, FJ ;
Chenevert, TL .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04) :642-651
[10]  
Milburn JM, 1997, AM J NEURORADIOL, V18, P1081