Noninvasive Continuous Monitoring of Tear Glucose Using Glucose-Sensing Contact Lenses

被引:54
作者
Ascaso, Francisco J. [1 ,2 ,3 ]
Huerva, Valentin [4 ,5 ]
机构
[1] Univ Lozano Blesa, Hosp Clin, Dept Ophthalmol, Zaragoza, Spain
[2] Univ Zaragoza, Sch Med, Zaragoza, Spain
[3] Inst Invest Sanitaria Aragon, Zaragoza, Spain
[4] Univ Hosp Arnau de Vilanova, Dept Ophthalmol, Avda Alcalde Rovira Roure 80, Lleida 25198, Spain
[5] IRB Lleida, Lleida, Spain
关键词
electrochemical determination; contact lenses; biosensor; nanomaterials; diabetes mellitus; noninvasive diagnostic device; glucose control; tear glucose; fluorescence-based techniques; noninvasive continuous glucose monitoring; DIRECT ELECTRON-TRANSFER; DIABETES-MELLITUS; BIOFUEL CELL; POWER SOURCE; BIOSENSOR; SENSORS; SPECTROSCOPY; TEMPERATURE; ASSAY;
D O I
10.1097/OPX.0000000000000698
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
The incidence of diabetes mellitus is dramatically increasing in the developed countries. Tight control of blood glucose concentration is crucial to diabetic patients to prevent microvascular complications. Self-monitoring of blood glucose is widely used for controlling blood glucose levels and usually performed by an invasive test using a portable glucometer. Many technologies have been developed over the past decades with the purpose of obtaining a continuous physiological glycemic monitoring. A contact lens is the ideal vehicle for continuous tear glucose monitoring of glucose concentration in tear film. There are several research groups that are working in the development of contact lenses with embedded biosensors for continuously and noninvasively monitoring tear glucose levels. Although numerous aspects must be improved, contact lens technology is one step closer to helping diabetic subjects better manage their condition, and these contact lenses will be able to measure the level of glucose in the wearer's tears and communicate the information to a mobile phone or computer. This article reviews studies on ocular glucose and its monitoring methods as well as the attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors.
引用
收藏
页码:426 / 434
页数:9
相关论文
共 49 条
[1]
Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid [J].
Alexeev, VL ;
Das, S ;
Finegold, DN ;
Asher, SA .
CLINICAL CHEMISTRY, 2004, 50 (12) :2353-2360
[2]
Microfluidic Devices Integrating Microcavity Surface-Plasmon-Resonance Sensors: Glucose Oxidase Binding-Activity Detection [J].
Amarie, Dragos ;
Alileche, Abdelkrim ;
Dragnea, Bogdan ;
Glazier, James A. .
ANALYTICAL CHEMISTRY, 2010, 82 (01) :343-352
[3]
Photonic crystal carbohydrate sensors: Low ionic strength sugar sensing [J].
Asher, SA ;
Alexeev, VL ;
Goponenko, AV ;
Sharma, AC ;
Lednev, IK ;
Wilcox, CS ;
Finegold, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (11) :3322-3329
[4]
Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus [J].
Baca, Justin T. ;
Finegold, David N. ;
Asher, Sanford A. .
OCULAR SURFACE, 2007, 5 (04) :280-293
[5]
Wavelength-ratiometric probes for the selective detection of fluoride based on the 6-aminoquinolinium nucleus and boronic acid moiety [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
JOURNAL OF FLUORESCENCE, 2004, 14 (06) :693-703
[6]
Competitive-binding assay method based on fluorescence quenching of ligands held in close proximity by a multivalent receptor [J].
Ballerstadt, R ;
Schultz, JS .
ANALYTICA CHIMICA ACTA, 1997, 345 (1-3) :203-212
[7]
Fast responsive crystalline colloidal array photonic crystal glucose sensors [J].
Ben-Moshe, Matti ;
Alexeev, Vladimir L. ;
Asher, Sanford A. .
ANALYTICAL CHEMISTRY, 2006, 78 (14) :5149-5157
[8]
COLLECTION AND CONCENTRATION OF TEAR PROTEINS STUDIED BY SDS GEL-ELECTROPHORESIS - PRESENTATION OF A NEW METHOD WITH SPECIAL REFERENCE TO DRY EYE PATIENTS [J].
BJERRUM, KB ;
PRAUSE, JU .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1994, 232 (07) :402-405
[9]
Noninvasive glucose sensing utilizing a digital closed-loop polarimetric approach [J].
Cameron, BD ;
Cote, GL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) :1221-1227
[10]
Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment [J].
Chu, Ming Xing ;
Miyajima, Kumiko ;
Takahashi, Daishi ;
Arakawa, Takahiro ;
Sano, Kenji ;
Sawada, Shin-ichi ;
Kudo, Hiroyuki ;
Iwasaki, Yasuhiko ;
Akiyoshi, Kazunari ;
Mochizuki, Manabu ;
Mitsubayashi, Kohji .
TALANTA, 2011, 83 (03) :960-965