TuBaFrost 6:: Virtual microscopy in virtual tumour banking

被引:19
作者
Teodorovic, I.
Isabelle, M.
Carbone, A.
Passioukov, A.
Lejeune, S.
Jamine, D.
Therasse, P.
Gloghini, A.
Dinjens, W. N. M.
Lam, K. H.
Oomen, M. H. A.
Spatz, A.
Ratcliffe, C.
Knox, K.
Mager, R.
Kerr, D.
Pezzella, F.
van Damme, B.
van de Vijver, M.
van Boven, H.
Morente, M. M.
Alonso, S.
Kerjaschki, D.
Pammer, J.
Lopez-Guerrero, J. A.
Bosch, A. Llombart
van Veen, E. -B.
Oosterhuis, J. W.
Riegman, P. H. J.
机构
[1] EORTC Data Ctr, B-1200 Brussels, Belgium
[2] Ctr Riferimento Oncol, I-33081 Aviano, PN, Italy
[3] Erasmus MC, NL-3015 GE Rotterdam, Netherlands
[4] Inst Gustave Roussy, F-94805 Villejuif, France
[5] Univ Oxford, Radcliffe Infirm, Natl Translat Canc Res Network, Oxford OX2 6HE, England
[6] Univ Oxford, John Radcliffe Hosp, Nuffield Dept Clin Lab Sci, Oxford OX3 9DU, England
[7] UZKU Leuven, B-3000 Louvain, Belgium
[8] Netherlands Canc Inst, NL-1066 CX Amsterdam, Netherlands
[9] Ctr Nacl Invest Oncol, E-28029 Madrid, Spain
[10] Univ Vienna, Alllgemeines Krankenhaus, A-1090 Vienna, Austria
[11] Fundac Inst Valenciano Oncol, Valencia, Spain
[12] Medlaw Consult, NL-2502 AM The Hague, Netherlands
关键词
virtual microscope; virtual tumour bank; virtual bio-repository; virtual tissue banking;
D O I
10.1016/j.ejca.2006.04.033
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Many systems have already been designed and successfully used for sharing histology images over large distances, without transfer of the original glass slides. Rapid evolution was seen when digital images could be transferred over the Internet. Nowadays, sophisticated Virtual Microscope systems can be acquired, with the capability to quickly scan large batches of glass slides at high magnification and compress and store the large images on disc, which subsequently can be consulted through the Internet. The images are stored on an image server, which can give simple, easy to transfer pictures to the user specifying a certain magnification on any position in the scan. This offers new opportunities in histology review, overcoming the necessity of the dynamic telepathology systems to have compatible software systems and microscopes and in addition, an adequate connection of sufficient bandwidth. Consulting the images now only requires an Internet connection and a computer with a high quality monitor. A system of complete pathology review supporting bio-repositories is described, based on the implementation of this technique in the European Human Frozen Tamor Tissue Bank (TUBaFrost). (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3110 / 3116
页数:7
相关论文
共 20 条
[1]  
Afework A, 1998, J AM MED INFORM ASSN, P912
[2]   Digital pathology: Science fiction? [J].
Barbareschi, M ;
Demichelis, F ;
Forti, S ;
Dalla Palma, P .
INTERNATIONAL JOURNAL OF SURGICAL PATHOLOGY, 2000, 8 (04) :261-263
[3]   Telemicroscopy by the Internet revisited [J].
Brauchli, K ;
Christen, H ;
Haroske, G ;
Meyer, W ;
Kunze, KD ;
Oberholzer, M .
JOURNAL OF PATHOLOGY, 2002, 196 (02) :238-243
[4]  
COSTELLO SP, 2002, ARCH PATHOL LAB MED, V126, P781
[5]  
Costello SSP, 2002, BRIT J CANCER, V86, pS34
[6]   Digital storage of glass slides for quality assurance in histopathology and cytopathology [J].
Demichelis, F ;
Della Mea, V ;
Forti, S ;
Dalla Palma, P ;
Beltrami, CA .
JOURNAL OF TELEMEDICINE AND TELECARE, 2002, 8 (03) :138-142
[7]   Diagnostic accuracy of an international static-imaging telepathology consultation service [J].
Halliday, BE ;
Bhattacharyya, AK ;
Graham, AR ;
Davis, JR ;
Leavitt, SA ;
Nagle, RB ;
McLaughlin, WJ ;
Rivas, RA ;
Martinez, R ;
Krupinski, EA ;
Weinstein, RS .
HUMAN PATHOLOGY, 1997, 28 (01) :17-21
[8]  
Kaiser K, 2004, STUD HEALTH TECHNOL, V101, P61
[9]  
Lee Szu-Hee, 2005, Lab Hematol, V11, P38, DOI 10.1532/LH96.04059
[10]  
LEONG FJW, 1999, RECENT ADV HISTOPATH, P217