Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging

被引:119
作者
de Zwart, JA
van Gelderen, P
Kellman, P
Duyn, JH
机构
[1] NINDS, Adv MRI, Lab Funct & Mol Imaging, NIH, Bethesda, MD 20892 USA
[2] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
关键词
MRI; accelerated imaging; SENSE; brain imaging; fMRI; BOLD;
D O I
10.1002/mrm.10303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The benefits of sensitivity-encoded (SENSE) echo-planar imaging (EPI) for functional MRI (fMRI) based on blood oxygen level-dependent (BOLD) contrast were quantitatively investigated at 1.5 T. For experiments with 3.4 x 3.4 x 4.0 mm(3) resolution, SENSE allowed the single-shot EPI image acquisition duration to be shortened from 24.1 to 12.4 ms, resulting in a reduced sensitivity to geometric distortions and T-2* blurring. Finger-tapping fMRI experiments, performed on eight normal volunteers, showed an overall 18% loss in t-score in the activated area, which was substantially smaller than expected based on the image signal-to-noise ratio (SNR) and g-factor, but similar to the loss predicted by a model that takes physiologic noise into account.
引用
收藏
页码:1011 / 1020
页数:10
相关论文
共 33 条
[1]   Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE) [J].
Bammer, R ;
Keeling, SL ;
Augustin, M ;
Pruessmann, KP ;
Wolf, R ;
Stollberger, R ;
Hartung, HP ;
Fazekas, F .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :548-554
[2]   IMAGE-RECONSTRUCTION FOR ECHO PLANAR IMAGING WITH NONEQUIDISTANT KAPPA-SPACE SAMPLING [J].
BRUDER, H ;
FISCHER, H ;
REINFELDER, HE ;
SCHMITT, F .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :311-323
[3]   Reduction of gradient acoustic noise in MRI using SENSE-EPI [J].
de Zwart, JA ;
van Gelderen, P ;
Kellman, P ;
Duyn, JH .
NEUROIMAGE, 2002, 16 (04) :1151-1155
[4]   Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging [J].
de Zwart, JA ;
Ledden, PJ ;
Kellman, P ;
van Gelderen, P ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1218-1227
[5]  
DEZWART JA, 2001, P WORKSH MIN MR DAT, P153
[6]   MOTION ARTIFACTS IN FMRI - COMPARISON OF 2DFT WITH PR AND SPIRAL SCAN METHODS [J].
GLOVER, GH ;
LEE, AT .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :624-635
[7]  
Golay X, 2000, MAGNET RESON MED, V43, P779, DOI 10.1002/1522-2594(200006)43:6<779::AID-MRM1>3.0.CO
[8]  
2-4
[9]   NOISE CORRELATIONS IN DATA SIMULTANEOUSLY ACQUIRED FROM MULTIPLE SURFACE COIL ARRAYS [J].
HAYES, CE ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :181-191
[10]   FAST MRI DATA ACQUISITION USING MULTIPLE DETECTORS [J].
HUTCHINSON, M ;
RAFF, U .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (01) :87-91