Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging

被引:150
作者
de Zwart, JA
Ledden, PJ
Kellman, P
van Gelderen, P
Duyn, JH
机构
[1] NINCDS, LFMI, NIH, Bethesda, MD 20892 USA
[2] Nova Med, Wakefield, MA USA
[3] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
关键词
MRI; parallel imaging; SENSE; brain imaging; RF coil; sensitivity; SNR;
D O I
10.1002/mrm.10169
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An 8-channel receive-only detector array was developed for SENSE MRI of human brain. The coil geometry was based on a gapped element design and used ultra-high impedance preamplifiers for mutual decoupling of the elements. Computer simulations of the electric and magnetic fields showed that excellent signal-to-noise ratio (SNR) and SENSE performance could be achieved by placing the coil elements close to the head and maintaining a substantial gap between the elements. Measurements with a 1.5 T prototype coil showed a 2.7-fold improvement of the SNR averaged over the brain compared to a conventional quadrature birdcage receive coil and an average geometrical noise amplification factor (g-value) of 1.06 and 1.38 for rate-2 and rate-3 SENSE, respectively.
引用
收藏
页码:1218 / 1227
页数:10
相关论文
共 18 条
  • [1] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [2] DEZWART JA, 2001, P 9 SCI M ISMRM GLAS, P1217
  • [3] NOISE CORRELATIONS IN DATA SIMULTANEOUSLY ACQUIRED FROM MULTIPLE SURFACE COIL ARRAYS
    HAYES, CE
    ROEMER, PB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) : 181 - 191
  • [4] AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T
    HAYES, CE
    EDELSTEIN, WA
    SCHENCK, JF
    MUELLER, OM
    EASH, M
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) : 622 - 628
  • [5] HERLIHY DJ, 2000, P 8 ANN M ISMRM, P1394
  • [6] KELLMAN P, 2001, P ISMRM WORKSH MIN M, P121
  • [7] KING SB, 2001, P 9 ANN M ISMRM GLAS, P1090
  • [8] LEDDEN PJ, 2001, P 9 SCI M ISMRM GLAS, P1117
  • [9] BIOLOGICAL AND MEDICAL IMAGING BY NMR
    MANSFIELD, P
    PYKETT, IL
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1978, 29 (02) : 355 - 373
  • [10] A 16-element phased-array head coil
    Porter, JR
    Wright, SM
    Reykowski, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (02) : 272 - 279