摘要
Chiral separation for the analysis of enantiomers in biological fluids by HPLC often takes relatively long chromatography time compared to achiral analysis. The advantage of fast mass transfer in packed-column supercritical fluid chromatography (pSFC) and the high-flow compatibility of APCI-MS/MS were applied to develop a fast bioanalytical method for R/S-warfarin in human plasma. Presented here are the main challenges encountered during method development of a sermi-automated liquid extraction SFC-MS/MS method. The selection of internal standard, robustness of the SFC equipment, and carryover issues are discussed. The method has high-throughput: the chromatography time is at least two-fold faster than the our fastest previous method; and the liquid/liquid extraction time of 96 samples is less than 20 min using a Tecan Genesis (R) RSP 100 pipetting station and a Tomtec Quadra-96 (R) workstation. The standard curve range was 13.6-2500 ng/ml. Precision of QC concentrations from four validation runs was 7.0% for R-warfarin and 6.0% C.V. for S-warfarin; and the bias was 3.7 and 3.2% R.E., respectively. The method is sensitive, accurate, selective and robust, and was applied to a drug-interaction clinical study with rapid turnaround of sample analysis. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:573 / 580
页数:8
相关论文
共 11 条
[1]   PHENYLBUTAZONE-WARFARIN INTERACTION IN MAN - FURTHER STEREOCHEMICAL AND METABOLIC CONSIDERATIONS [J].
BANFIELD, C ;
OREILLY, R ;
CHAN, E ;
ROWLAND, M .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1983, 16 (06) :669-675
[2]   Supercritical fluid chromatography coupled to electrospray mass spectrometry: a powerful tool for the analysis of chiral mixtures [J].
Garzotti, M ;
Hamdan, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 770 (1-2) :53-61
[3]   Comparison of packed column supercritical fluid chromatography-tandem mass spectrometry with liquid chromatography-tandem mass spectrometry for bioanalytical determination of (R)- and (S)-ketoprofen in human plasma following automated 96 well solid-phase extraction [J].
Hoke, SH ;
Pinkston, JD ;
Bailey, RE ;
Tanguay, SL ;
Eichhold, TH .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4235-4241
[4]   Increasing bioanalytical throughput using pcSFC-MS/MS: 10 minutes per 96-well plate [J].
Hoke, SH ;
Tomlinson, JA ;
Bolden, RD ;
Morand, KL ;
Pinkston, JD ;
Wehmeyer, KR .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :3083-3088
[5]   Warfarin dosing and cytochrome P4502C9 polymorphisms [J].
Joffe, HV ;
Xu, RL ;
Johnson, FB ;
Longtine, J ;
Kucher, N ;
Goldhaber, SZ .
THROMBOSIS AND HAEMOSTASIS, 2004, 91 (06) :1123-1128
[6]   Effects of oral vitamin K on S- and R-Warfarin pharmacokinetics and pharmacodynamics: Enhanced safety of warfarin as a CYP2C9 probe [J].
Kim, JS ;
Nafziger, AN ;
Gaedigk, A ;
Dickmann, LJ ;
Rettie, AE ;
Bertino, JS .
JOURNAL OF CLINICAL PHARMACOLOGY, 2001, 41 (07) :715-722
[7]   Development and validation of a sensitive and robust LC-tandem MS method for the analysis of warfarin enantiomers in human plasma [J].
Naidong, W ;
Ring, PR ;
Midtlien, C ;
Jiang, XY .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (02) :219-226
[8]   Chiral bioanalysis of warfarin using microbore LC with peak compression [J].
Prangle, AS ;
Noctor, TAG ;
Lough, WJ .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (07) :1205-1212
[9]   Validation of a method for the determination of (R)-warfarin and (S)-warfarin in human plasma using LC with UV detection [J].
Ring, PR ;
Bostick, JM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (03) :573-581
[10]   DEVELOPMENT AND VALIDATION OF A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE QUANTITATION OF WARFARIN ENANTIOMERS IN HUMAN PLASMA [J].
WENG, ND ;
LEE, JW .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (09) :785-792