Two- and three-dimensional MR coronary angiography with intraarterial injections of contrast agent in dogs: A feasibility study

被引:21
作者
Green, JD
Omary, RA
Finn, JP
Chung, YC
Tang, R
Li, YZ
Vasireddy, S
Li, DB
机构
[1] Northwestern Univ, Sch Med, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Sch Med, Dept Biomed Engn, Chicago, IL 60611 USA
[3] Siemens Med Solut, Chicago, IL USA
关键词
animals; coronary vessels; MR; interventional procedures; experimental studies; magnetic resonance (MR); contrast enhancement; guidance; vascular studies;
D O I
10.1148/radiol.2261011848
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance (MR) images of coronary arteries were acquired with an inversion recovery-prepared technique after intraarterial injection of contrast material in five dogs. Real-time two-dimensional projection images were obtained with a temporal resolution of 3 frames per second. Three-dimensional electrocardiographically triggered high-spatial-resolution images were obtained with a fraction of the contrast agent required for intravenous injections. Background tissues were adequately suppressed in all images. On the basis of this experimental data, the optimal contrast agent concentration for two-dimensional real-time projection imaging was 6%. This preliminary work shows that contrast material-enhanced MR angiography with intraarterial injections is feasible with the proposed techniques. (C) RSNA, 2002.
引用
收藏
页码:272 / 277
页数:6
相关论文
共 18 条
[1]   Background suppression using magnetization preparation for contrast-enhanced MR projection angiography [J].
Bos, C ;
Bakker, CJG ;
Viergever, MA .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :78-87
[2]   PROJECTION ANGIOGRAMS OF BLOOD LABELED BY ADIABATIC FAST PASSAGE [J].
DIXON, WT ;
DU, LN ;
FAUL, DD ;
GADO, M ;
ROSSNICK, S .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (03) :454-462
[3]  
Haacke M.E., 1999, MAGNETIC RESONANCE I, Vfirst, P51
[4]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[5]  
Hofman MBM, 1999, MAGN RESON MED, V41, P360, DOI 10.1002/(SICI)1522-2594(199902)41:2<360::AID-MRM21>3.0.CO
[6]  
2-C
[7]   The use of contrast-enhanced magnetic resonance imaging to identify reversible myocardial dysfunction. [J].
Kim, RJ ;
Wu, E ;
Rafael, A ;
Chen, EL ;
Parker, MA ;
Simonetti, O ;
Klocke, FJ ;
Bonow, RO ;
Judd, RM .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (20) :1445-1453
[8]  
Kleinbaum DG., 2007, Applied Regression Analysis and Multivariable Methods, V4th ed
[9]   Contrast-enhanced MR imaging of coronary arteries: Comparison of intra- and extravascular contrast agents in swine [J].
Li, DB ;
Zheng, J ;
Weinmann, HJ .
RADIOLOGY, 2001, 218 (03) :670-678
[10]   Intraarterial gadolinium-enhanced 2D and 3D MR angiography: A preliminary study [J].
Omary, RA ;
Frayne, R ;
Unal, O ;
Grist, TM ;
Strother, CM .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (10) :1315-1321