A spatial and temporal comparison of hemodynamic signals measured using optical and functional magnetic resonance imaging during activation in the human primary visual cortex

被引:92
作者
Toronov, Vladislav Y.
Zhang, Xiaofeng
Webb, Andrew G.
机构
[1] Penn State Univ, Dept Bioengn, University Pk, PA 16802 USA
[2] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
关键词
human brain; functional activity; near infrared imaging; fMRI;
D O I
10.1016/j.neuroimage.2006.08.048
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Functional near infrared spectro-imaging (fNIRSI) is potentially a very useful technique for obtaining information about the underlying physiology of the blood oxygenation level dependent (BOLD) signal used in functional magnetic resonance imaging (fMRI). In this paper the temporal and spatial statistical characteristics of fNIRSI data are compared to those of simultaneously acquired fMRI data in the human visual cortex during a variable-frequency reversing checkerboard activation paradigm. Changes in the size of activated volume caused by changes in checkerboard reversal frequency allowed a comparison of the behavior of the spatial responses measured by the two imaging methods. fNIRSI and fMRI data were each analyzed using standard correlation and fixed-effect group analyses of variance pathways. The statistical significance of MIRSI data was found to be much lower than that of the fMRI data, due mainly to the low signal-to-noise of the measurements. Reconstructed images also showed that, while the time-course of changes in the oxy-, deoxy-, and total hemoglobin concentrations all exhibit high correlation with that of the BOLD response, the changes in the volume of tissue measured as "activated" by the BOLD response demonstrate a closer similarity to the corresponding changes in the oxy- and total hemoglobin concentrations than to that of the deoxyhemoglobin. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:1136 / 1148
页数:13
相关论文
共 50 条
[1]   Optical tomography in medical imaging [J].
Arridge, SR .
INVERSE PROBLEMS, 1999, 15 (02) :R41-R93
[2]  
ARRIDGE SR, 1986, INFORMATION PROCESSI, P155
[3]   Three-dimensional optical tomography of hemodynamics in the human head [J].
Bluestone, AY ;
Abdoulaev, G ;
Schmitz, CH ;
Barbour, RL ;
Hielscher, AH .
OPTICS EXPRESS, 2001, 9 (06) :272-286
[4]   Simulation study of magnetic resonance imaging-guided cortically constrained diffuse optical tomography of human brain function [J].
Boas, DA ;
Dale, AM .
APPLIED OPTICS, 2005, 44 (10) :1957-1968
[5]   Diffuse optical imaging of brain activation: approaches to optimizing image sensitivity, resolution, and accuracy [J].
Boas, DA ;
Dale, AM ;
Franceschini, MA .
NEUROIMAGE, 2004, 23 :S275-S288
[6]   Improving the diffuse optical imaging spatial resolution of the cerebral hemodynamic response to brain activation in humans [J].
Boas, DA ;
Chen, K ;
Grebert, D ;
Franceschini, MA .
OPTICS LETTERS, 2004, 29 (13) :1506-1508
[7]   Quantitative spectroscopic diffuse optical tomography of the breast guided by imperfect a ptiori structural information [J].
Boverman, G ;
Miller, EL ;
Ang, L ;
Zhang, Q ;
Chaves, T ;
Brooks, DH ;
Boas, DA .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (17) :3941-3956
[8]   Dynamics of blood flow and oxygenation changes during brain activation: The balloon model [J].
Buxton, RB ;
Wong, EC ;
Frank, LR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :855-864
[9]  
CHARLES PD, 1994, NEUROLOGY, V44, pA184
[10]   Simultaneous near-infrared spectroscopy monitoring of left and right occipital areas reveals contra-lateral hemodynamic changes upon hemi-field paradigm [J].
Colier, WNJM ;
Quaresima, V ;
Wenzel, R ;
van der Sluijs, MC ;
Oeseburg, B ;
Ferrari, M ;
Villringer, A .
VISION RESEARCH, 2001, 41 (01) :97-102