Polymeric monolithic stationary phases for capillary electrochromatography

被引:114
作者
Hilder, EF
Svec, F
Fréchet, JMJ
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, EO Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
关键词
capillary electrochromatography; column technology; monolith; porous polymer; review;
D O I
10.1002/elps.200290011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This review summarizes the contributions of a number of groups working in the rapidly growing area of monolithic columns for capillary electrochromatography (CEC), with a focus on those prepared from synthetic polymers. Monoliths have quickly become a well-established stationary phase format in the field of CEC. The simplicity of their in situ preparation method as well as the good control over their porous properties and surface chemistries make the monolithic separation media an attractive alternative to capillary columns packed with particulate materials. A wide variety of approaches as well as materials used for the preparation of the monolithic stationary phases are detailed. Their excellent chromatographic performance is demonstrated by numerous separations of different analytes.
引用
收藏
页码:3934 / 3953
页数:20
相关论文
共 116 条
  • [91] Design of the monolithic polymers used in capillary electrochromatography columns
    Svec, F
    Peters, EC
    Sykora, D
    Fréchet, JMJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) : 3 - 29
  • [92] Column technology for capillary electrochromatography
    Tang, QL
    Lee, ML
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (11) : 648 - 663
  • [93] Monolithic columns containing sol-gel bonded octadecylsilica for capillary electrochromatography
    Tang, QL
    Xin, BM
    Lee, ML
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 837 (1-2) : 35 - 50
  • [94] Electrochromatography in microchips: Reversed-phase separation of peptides and amino acids using photopatterned rigid polymer monoliths
    Throckmorton, DJ
    Shepodd, TJ
    Singh, AK
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (04) : 784 - 789
  • [95] TSUDA T, 1982, J CHROMATOGR, V248, P241, DOI 10.1016/S0021-9673(00)87275-1
  • [96] Vanhoenacker G, 2001, ELECTROPHORESIS, V22, P4064, DOI 10.1002/1522-2683(200111)22:19<4064::AID-ELPS4064>3.0.CO
  • [97] 2-9
  • [98] Végvári A, 2000, ELECTROPHORESIS, V21, P3116, DOI 10.1002/1522-2683(20000901)21:15<3116::AID-ELPS3116>3.3.CO
  • [99] 2-X
  • [100] Pore flow effects in electrically driven size-exclusion chromatography
    Venema, E
    Kraak, JC
    Poppe, H
    Tijssen, R
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 837 (1-2) : 3 - 15