Partial discharge inception characteristics under butt gap condition in liquid nitrogen/PPLP® composite insulation system for high temperature superconducting cable

被引:20
作者
Hazeyama, M
Kobayashi, T
Hayakawa, N
Honjo, S
Masuda, T
Okubo, H
机构
[1] Nagoya Univ, Dept Elect Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Tokyo Elect Power Co Ltd, Yokohama, Kanagawa, Japan
[3] Sumitomo Elect Ind Ltd, Osaka, Japan
关键词
D O I
10.1109/TDEI.2002.1115487
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The partial discharge (PD) inception characteristics are studied in liquid nitrogen (LN2)/polypropylene laminated paper (PPLP(R)) composite insulation system for high temperature superconducting (HTS) cable. Experimental results revealed that the magnitude of the initial PD increased as the PD inception electric field strength was increased, because the injected energy increased. Initial PD was generated at the first and third quadrant of applied ac voltage phase. The probability of initial PD at the positive and negative voltage phase was almost the same. The reason is because liquid nitrogen is nonpolar molecule and we used symmetric electrode configuration with uniform electric field distribution. Finally, it was pointed out that PD inception electric field strength (PDIE) depended on the volume of the butt gap because of the increasing probability of weak points of electrical insulation, and PDIE linearly decreased with increasing stressed volume of the butt gap in the log-log scale.
引用
收藏
页码:939 / 944
页数:6
相关论文
共 10 条
[1]   High voltage insulation for power cables utilizing high temperature superconductivity [J].
Bulinski, A ;
Densley, J .
IEEE ELECTRICAL INSULATION MAGAZINE, 1999, 15 (02) :14-22
[2]   Cryogenic electrical insulation of superconducting power transmission lines: transfer of experience learned from metal superconductors to high critical temperature superconductors [J].
Gerhold, J ;
Tanaka, T .
CRYOGENICS, 1998, 38 (11) :1173-1188
[3]  
HATHAWAY GM, 1999, 11 INT S HIGH VOLT E, V4, P84
[4]  
HAZEYAMA M, 2001, 5 EUR C APPL SUP
[5]   Present status of the development of superconducting power cable [J].
Honjo, S ;
Mimura, T ;
Takahashi, Y .
PHYSICA C, 2000, 335 (1-4) :11-14
[6]  
LADIE PL, 1999, P JIC, P103
[7]  
MASUDA T, 2001, 5 EUR C APPL SUP
[8]   High voltage insulation performance of cryogenic liquids for superconducting power apparatus [J].
Okubo, H ;
Hikita, M ;
Goshima, H ;
Sakakibara, H ;
Hayakawa, N .
IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) :1400-1406
[9]   Installation and operation of the Southwire 30-meter high-temperature superconducting power cable [J].
Stovall, JP ;
Demko, JA ;
Fisher, PW ;
Gouge, MJ ;
Lue, JW ;
Sinha, UK ;
Armstrong, JW ;
Hughey, RL ;
Lindsay, D ;
Tolbert, JC .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) :2467-2472
[10]   DIELECTRIC INSULATION CHARACTERISTICS OF LIQUID-NITROGEN-IMPREGNATED LAMINATED PAPER-INSULATED CABLE [J].
SUZUKI, H ;
ISHIHARA, K ;
AKITA, S .
IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (04) :1677-1680